IS-MDC-12 Instruction Manual
CEB00249-53-000
Page 9 of 12
Issue 3 19 January 2021
Extending the Lead
The lead fitted to the door switch is usually not long enough to reach the control panel and will need
to be extended using low voltage stranded multicore cable. Unless the cable run is exceptionally
long, cable with 7/0.2mm cores are suitable. Six core cable is required unless connecting to an ICS-6,
where only four cores are necessary. Lasermet can supply suitable cable to match that fitted to the
switch.
5.3 Final Testing
Once the panel is fully wired the system may be tested according to the ICS instruction manual or
specific instruction procedures.
The final position of the switch should be adjusted so that the system is disabled before the door or
cover is sufficiently opened to present a hazard to those outside.
Once the final position of the switch and actuator have been set, they may be secured by fully
tightening the screws. The screw caps should then be fitted to cover them. Note that all four caps
are different, and care should be taken to fit the right ones in the right places.