12
Specifications
Safety Performance
Up to PL’e’ to EN ISO 13849-1:2015 see section 4.
Shutdown Time
6ms typical.
Measured from opening of safety circuits to opening of interlock
operator contacts.
Maximum Safety
220Ω at 24V supply voltage
Loop Resistance
140 Ω at 21.5V supply voltage
Supply Voltage
24V DC (21.5 – 26.5V)
Power Consumption
15W typical (ICS-6-OEM only)
No. of Output Contacts
7 dual channel
Output Contact Rating
4A 50VDC resistive load
Ingress Protection
IP20
Operating Conditions
0° to 55°C, 0% - 95% relative humidity non-condensing.
Size
210mm wide X 90mm high X 55mm over DIN rail
Weight
650g
Dimensions are approximate. Values given as ‘typical’ are average values measured across a number
of samples and are not guaranteed. Lasermet reserve the right to alter any specification without
prior notice.
Safety Performance
This product is certified to Performance Level ‘e’ (PLe) to EN ISO 13849-1:2015.
When connected to an interlock control system as shown in this manual, the ICS-6-OEM has the
following characteristics. This can also be achieved by correctly connecting to another suitable safety
control system which has dual channel monitoring of the shutdown device.
Mean time to dangerous failure (MTTF
d
)
381 years
Probability of dangerous failure per hour (PFH)
2.47 x 10
-8
It is important to note that the Performance Level established for the ICS-6-OEM are those that may
be achieved by the system when the board is properly integrated into a safety related part of a
control system.