Concept 

 
I-Extract is Lasermet’s fume extraction system specifically designed for the extraction and filtration 
of  gases  and  emissions  created  by  lasers  during  laser  welding,  laser  cutting  and  laser  cladding 
processes. 
 
Designed  as  an  integrated  part  of  Lasermet’s  “Laser  Castle”  laser  safety  cabin,  the  I-Extract  has 
ample power to extract the appropriate volume of emitted gases produced in the cabin. 
 
The specific CFM (cubic feet per minute) figures are available for specific cabins. 
 
A powerful, three phase electric motor powers the extraction fan. 
 
The overall enclosure is manufactured using galvanised sheet metal with a powder coated finish. 
 
Lasermet  provides  a  full  range  of  laser  interlock  equipment  including  control  systems,  interlock 
switches,  illuminated  warning  signs,  laser  shutters,  door  locks,  external  power  supplies  etc.  which 
can be connected to provide a complete laser interlock system. Full support, design and installation 
is available from Lasermet, please contact us for any queries. Contact details are given at the end of 
this manual. 
 
 

Filters 

 
One  HEPA  Filter  (High-efficiency 
particulate  arrestance)  individually 
tested  to  EN1822:2009  H3,  and  two 
further  filters  tested  to  EN779:2012 
Filter Class M6. 

 

 

Approvals

 

 

 

 

I-Extract 

High Efficiency Laser Fume Extraction System 

– complete unit 

 

Содержание I-EXTRACT

Страница 1: ...I Extract Instruction Manual CEB00XXX 53 000 Issue 2 30 January 2020 LASERMET I EXTRACT INSTRUCTION MANUAL FUME EXTRACTION SYSTEM Issue 2 ...

Страница 2: ...30 January 2020 LASERMET I EXTRACT Instruction Manual Contents 1 Safety Warnings 3 2 Concept 4 3 Assembly 5 4 Filter 6 4 1 Replacement Schedule 6 4 2 Filter Change 6 4 3 Pre Filter Change 7 4 4 HEPA Filter Change 8 5 Specifications 9 6 Warranty 10 7 Contact Details 11 ...

Страница 3: ...e to tamper with the parts open them or use them outside of the parameters contained herein The units are only designed to be fixed to surfaces using their inbuilt fixing holes They must not come into contact with each other or any other moving part when in use The parts should never be subject to impact or mechanical strain Safety switches should never be defeated or bypassed It is imperative tha...

Страница 4: ...se electric motor powers the extraction fan The overall enclosure is manufactured using galvanised sheet metal with a powder coated finish Lasermet provides a full range of laser interlock equipment including control systems interlock switches illuminated warning signs laser shutters door locks external power supplies etc which can be connected to provide a complete laser interlock system Full sup...

Страница 5: ...Instruction Manual CEB00XXX 53 000 Page 5 of 11 Issue 2 30 January 2020 3 Assembly 1 Lift position and secure filter section 2 Lift position and secure fan assembly and silencer Use mastic sealer between flanges ...

Страница 6: ...ilters replaced when the first of the following occurs 1 The M6 reaches final pressure drop 250Pa The H13 reaches final pressure drop 600Pa 2 Each filter reaches 2 5 times its initial pressure drop 3 The pre filter has been installed for 1 year the final filter 3 years 4 2 Filter Change To remove the filter cells it is necessary to remove the filter access doors These are secured by hand knobs so ...

Страница 7: ...er Change 1 Remove lower access door 2 Pull out the old filter from the filter slide section and dispose of according to local regulations 3 Check brush seal is in good condition and does not need replacing reapplying 4 Refit access door and tighten hand knobs until tight Check door seal is good ...

Страница 8: ...t the old filter from the filter section and dispose of according to local regulations 4 Insert new filter taking care to respect any airflow indication arrow The filter seal should face upwards to seal against the filter housing sealing face 5 Clamp the new filter by pulling the lever arm of the cambars into the vertical position 6 Refit access door and tighten hand knobs until tight 7 Check door...

Страница 9: ...culate arrestance Media Glass fibre Separator Hot melt beads Sealant Polyurethane 2k sealant Filter Class according to EN1822 2009 H13 MPPS Efficiency H13 99 95 H14 99 995 Maximum Pressure Drop 600Pa Nominal Drop 250Pa Temperature Humidity 70 C 100 RH Dimensions Size 289W x 595H x 292D mm Area 0 16m Air Flow 1300m min Volume 0 06m Filter Weight 8 5kg High efficiency Compact Filter x 2 M6 Frame Wat...

Страница 10: ...pleted by Lasermet are covered against defects in workmanship for 12 months All filters in the fume extraction system must be replaced with Lasermet filters in accordance with the specification in this manual Damage or defects caused by other factors are not covered For example industrial contamination incorrect cleaning storm damage Consequential loss is not covered under warranty Compensation fo...

Страница 11: ...provide a complete system We also supply equipment and consultancy covering all aspects of laser safety Full support design and installation is available from Lasermet please contact us for any queries For sales and technical support Lasermet Ltd Lasermet House 137 Hankinson Road Bournemouth BH9 1HR United Kingdom Tel 44 0 1202 770740 Fax 44 0 1202 770730 Email sales lasermet com Website www laser...

Отзывы: