PLMNL0232 REV. H Effective Date: 01/14/19
15
FiberCUT
®
2D Operation Manual
If the beam is not centered,
continue to step 11.
See
Figure 14
Beam is NOT centered with the
Lens at the Bottom of Travel
13. Use a 3mm hex wrench to
loosen the (4) M5 LHCS on the
collimator approximately 1/4
turn each.
These screws use Belleville
washers that apply some
spring force when the
screws are slightly loose.
Centering in the X and
Y direction should be
adequate when the (3)
sides of the electronic
box and collimator body
are flush, as shown in
If necessary, it is possible to make
small adjustments to center the
beam by moving the collimator
body.
If desired, move the collimator
body slightly in the X and/or Y
direction.
14. Move the focus lens from
bottom of travel to top of travel
and view the beam position in
the nozzle orifice.
If the beam is centered,
tighten the (4) M5 LHCS on
the collimator. No further
adjustments are necessary.
If the beam is not centered,
repeat steps 8
– 13 until it
is.
Figure 15