14
B
C
2,5 m
< 1 mm = OK
Checking the vertical line:
Position the device about 5 m from a wall. Fix a plumb bob with a line of
2.5 m length on the wall, making sure that the bob can swing freely. Switch
on the device and align the vertical laser to the plumb line. The precision is
within the specified tolerance if the deviation between the laser line and the
plumb line is not greater than ± 1 mm.
Checking the horizontal line:
Position the device about 5 m from a wall
and switch on the cross laser. Mark point B
on the wall. Turn the laser cross approx. 2.5 m
to the right and mark point C. Check whether
the horizontal line from point C is level with point B to within ± 1 mm.
Repeat the process by turning the laser to the left.
Regularly check the calibration before use, after transport and after
extended periods of storage.
!
EN
Technical data
Self-levelling range
± 2.5°
Accuracy
± 0.2 mm / m
Operating range (depending on room illumination)
20 m
Working range with hand receiver (depends on how
the technology affects the difference in brightness)
50 m
Laser wavelength
635 nm
Laser class
2 / < 1 mW
Power supply
4 x 1.5 V alkaline
batteries (type AA, LR6)
Operating time
with 3 laser levels
with 2 laser levels
with 1 laser level
approx. 4 hours
approx. 10 hours
approx. 25 hours
Operating temperature
0°C ... +50°C
Storage temperature
-10°C ... +70°C
Dimensions (W x H x D)
85 x 130 x 155 mm
Weight (incl. batteries and alignment edge)
875 g
Subject to technical changes without notice. 01.2017