When measuring resistance, to avoid the risk of the results
of a measurement being distorted, there must be no traces of
dirt, oil, solder spray or other contamination on the test prods.
!
= 17.28 k
Ω
If "1" appears on the display instead of a measured value, either the
measuring range has been exceeded or the measuring circuit is not
closed or has been interrupted.
Resistances can only be measured correctly in isolation; therefore,
the components might need to be disconnected from the remainder
of the circuit.
black
red
Resistance measurement
To measure resistance, set the
rotary switch to the "Ω" position
with the corresponding measuring
range (200 Ω - 2,000 kΩ).
Then connect the measuring
contacts to the object to be
tested. The measured value
acquired appears on the display.