10
A1
A2
2.
1.
A3
A2
A2
A1
4.
3.
A3
A2
<
0,5 mm / m = OK
B
C
2,5 m
< 2,5 mm = OK
Regularly check the calibration before use, after transport
and after extended periods of storage.
!
Checking the horizontal line
Position the device about 5 m from a wall
and switch on the cross laser. Mark point B
on the wall. Turn the laser cross approx. 2.5 m
to the right and mark point C. Check whether
the horizontal line from point C is level with point B to within ± 2.5 mm.
Repeat the process by turning the laser to the left.
Checking the vertical line
Position the device about 5 m from a wall. Fix a plumb bob with
a line of 2.5 m length on the wall, making sure that the bob can
swing freely. Switch on the device and align the vertical laser to
the plumb line. The precision is within the specified tolerance if the
deviation between the laser line and the plumb line is not greater
than ± 2.5 mm.
When A2 and A3 are more than 0.5 mm / m apart,
an adjustment is necessary. Contact your authorised dealer
or else the UMAREX-LASERLINER Service Department.
!
Performing the calibration check
3.
Position the device as near as possible to the wall
at the height of point A1.
4.
Turn the device through 180° and mark point A3.
The difference between points A2 and A3 is the tolerance.
1.
Mark point A1 on the wall.
2.
Turn the device through 180° and mark point A2.
You now have a horizontal reference between points A1 and A2.
EN
Содержание EasyCross-Laser Green