LaserLiner DigiLevel Pro 120 Скачать руководство пользователя страница 3

DigiLevel Pro 30/60/120

GB

08

GB

09

Keypad

1.

 

(REF) – 

Angle reference value setting

2.

  

(     ) – 

ON / OFF switch

3.

 

)

)

) ) – 

Acoustic signal on/off

4.

 

(MR) – 

Memory retrieval

5.

   

(UNIT) – 

Unit of measurement selection

(° degrees / % / IN/FT)

6.

 

(M) – 

MEMORY function

Display

  7.

 Slope direction

  

8. 

Slope angle

  

9.

 Current memory position (M1 – M9)

10.

 Battery charge

DigiLevel Pro 30/60/120

11.

 Vertical vial

12.

 Horizontal vial

13.

 Magnets

14.

 Measuring surface, 30 / 60 / 120 cm

15.

 Point laser ON / OFF

16.

 Tripod threads, 1/4" 

Rear

17 .

 Battery compartment

1

Inserting batteries:

Open the battery compartment (17) on the rear of the DigiLevel and 
insert two new batteries (type AAA/LR03) in the manner indicated 
by the installation symbols. Ensure correct polarity. The symbol (10)
indicates the level of battery charge.

Digital electronic spirit level with vertical and horizontal angle display and 
point laser (650 nm).The slope can be indicated in degrees, IN/FT or percent 
on the display.An acoustic signal indicates the horizontal or vertical position.
The slope memory enables angles to be projected elsewhere, while
the separate measurement memory allows up to 9 measurements results 
to be stored and retrieved. Milled measuring surfaces, powerful 

fi

 xing 

magnets, as well as additional vertical and horizontal vial, illuminated display. 
Calibration function for increased accuracy and adaptation to measuring 
surface.

Switching on and measuring:

The DigiLevel Pro can measure angles continuously to 360°.

• Switch the DigiLevel Pro on using the on/off switch (2).

• The current operating temperature in °C is shown for a few seconds.

•  The slope angle is shown in the display (8). If slopes are measured

overhead, the direction of display adjusts automatically.

• The current slope direction is also shown by the symbol (7).

Selection of unit of measurement:

•  Button (5) allows the desired unit of measurement to be selected

(° degrees, %, IN/FT)

Changing the angle reference value:

•  With button (1), it is possible to transfer angles elsewhere. To do so, 

set the device to the desired slope and press button (1). The display will 
then change to “0.0”, and the desired reference angle is now set. 
The slope can now be transferred to other objects.

IMPORTANT:

 When all the slopes have been transferred, make sure

to deactivate the new angle reference value. To do this, switch off
the device by pressing the on/off switch (2) for at least 3 secs. Only
then will the value be reset itself to the measuring surface (14).

Acoustic signal:

• The acoustic signal can be switched on or off with button (3).

• When the angle of slope stands at 0°, 45°, 90° or the most recently 
stored value, this is indicated by an acoustic signal.

NOTE:

 When working with a changed angle reference value, the

acoustic signal is activated on reaching the new reference value

(0°, 45°, 90° display).

2

3

5

6

4

11

12

13

14

15

17

16

9

7

10

8