12
EN
Press the ZOOM button to
increase the sensitivity of the
device (12 V AC to 1000 V AC).
This enables voltage fields to be
located at significant distance by
moving the device over the area
to be tested.
The detector tip lights orange
when the ZOOM button is
pressed.
When voltage is present, the
detector tip lights red and a signal
sounds at 1-second intervals.
Please be aware that even if a visual signal is not displayed,
voltage may still be present. Differences in the design of
the connection socket or the nature of the insulation
(thickness and type) can affect functionality. Voltage cannot
be detected behind panels and metal covers.
!
For safety, check all three phase conductors (L1, L2, L3)
for the presence of voltage!
!
If the acoustic signal is weak or the battery lamp is not as
bright as it should be, replace the batteries.
!
4
ZOOM function
5
6
Battery lamp
Acoustic signal
Press button 5 to switch the flashlight on and off.
To switch off acoustic signal:
Device is off: Press and hold ON/OFF button (2) until the detector
tip lights green.
Device is on: Press and hold ON/OFF button (2) until the detector
tip flashes green.
To switch on acoustic signal:
Press and hold ON/OFF button (2) until the detector tip flashes
green and a signal sounds.