LTI MapStar TruAngle User’s Manual 3rd Edition

Section #3 - Using the TruAngle

Page 7

Fine Adjust and Friction Lock

The Fine Adjust wheel lets you precisely control the encoder’s rotation. Movement of the wheel results in 

small angle update measurements. The Fine Adjust ratio is 66:1.

Tightening the Friction Lock keeps the encoder from rotating by adding friction to the base plate and to 

the brake shoe which is attached to the chassis. Adjust as needed.

Button Names and Functions

Power ON the TruAngle

To power on the TruAngle, long press the ON button. Briefly, the LCD should look like Figure #8 and 

the backlight will also be on. Next the LCD should look like Figure #9, prompting you to index the 

encoder 

(Page 9)

.

Button

Function

Figure #7

ON

Long press powers on the TruAngle.

Shows the Display Test at power on until the 

button is released 

(Page 8)

.

BL

When the TruAngle is already powered on, long 

press to turn on / off the backlight.

OK

Short press to accept orientation and reference 

the TruAngle at the value displayed.

ZERO

Long press to activate the Zero Mode.

BS

Short press to activate the Backsight Mode.

Press and hold both buttons until the TruAngle 

powers off.

This manual simplifies the button names to relate to current function 

instead of matching the TruAngle’s label. For example, instead of 

“Press 

the ON BL OK button to activate the backlight”

, this manual would state 

“Press the BL button to activate the backlight”

Figure #8

Figure #9

Содержание MapStar TruAngle

Страница 1: ... LTI 2014 MapStar TruAngle 0144849 Laser Technology Inc MapStar TruAngle User s Manual ...

Страница 2: ...opyright c 2010 2014 Laser Technology Inc All Rights Reserved Unauthorized duplication in whole or in part is strictly prohibited First Edition December 2010 Second Edition January 2012 Third Edition November 2014 Trademarks MapStar TruAngle TruPulse TruSpeed Impulse UltraLyte and Criterion are registered trademarks of Laser Technology Inc All other trademarks are the property of their respective ...

Страница 3: ... Display Segment Test 8 Power OFF the TruAngle 8 Display the Firmware Version Number 8 Turn the LCD Backlight On or Off 8 Indexing the Encoder 9 Zeroing the Unit 9 Entering A Non Zero Backsight 9 Removing the Non Zero Backsight Value 10 Taking a Measurement 10 Error Codes 10 Section 4 Managing Serial Data 11 NMEA Compliance 11 Laser Settings 11 Remote Triggering 11 Format Parameters 12 Serial Port...

Страница 4: ... to any desired point or direction It works in conjunction with all our laser rangefinders that have an inclinometer for complete 3D position measurements with X Y and Z coordinates The modular design allows you to pivot the laser a full 90 up or down while maintaining the rotary encoder level providing the greatest possible accuracy and range of motion One of the major advantages of the TruAngle ...

Страница 5: ...art 1 Install the batteries Page 4 2 Mount side brackets laser tripod and then attach cables Pages 5 6 3 Use the bubble level to level the unit Page 6 4 Long press the ON button to power on the unit Page 7 5 Index the encoder Page 9 6 Zero the unit when 0 00 is flashing by pressing the OK button or firing the laser When the TruAngle is rotated the display not flash and will update with angle measu...

Страница 6: ...ure the Battery Door by turning the screw clockwise Figure 3 Battery Indicator Use a flat head screwdriver or coin to remove or secure the battery door The TruAngle continuously monitors its power source LTI has defined the acceptable battery voltage range to guarantee correct operation The battery voltage icon is located in the lower right corner of the LCD When the battery voltage becomes too lo...

Страница 7: ...esigned for use with the UltraLyte 3 Attach the laser mounting bracket to the side bracket The side bracket should be secure but should not be over tightened The required laser mounting bracket depends upon which laser you are using Impulse TruPulse 200 TruPulse 200X TruPulse 360 TruPulse 360R TruSpeed Sx or UltraLyte Please contact LTI if you need assistance When attaching the laser to the side b...

Страница 8: ...s the side bracket design includes a cable crimp You can use the cable crimp to hold the cables and keep them from interfering with your work Leveling the TruAngle The bubble level is used to level the TruAngle 1 Look at the position of the bubble within the bubble level When the bubble is centered inside the circle the TruAngle is level 2 To align the bubble within the circle adjust the tribach o...

Страница 9: ... also be on Next the LCD should look like Figure 9 prompting you to index the encoder Page 9 Button Function Figure 7 ON Long press powers on the TruAngle Shows the Display Test at power on until the button is released Page 8 BL When the TruAngle is already powered on long press to turn on off the backlight OK Short press to accept orientation and reference the TruAngle at the value displayed ZERO...

Страница 10: ...uttons As an example Figure 10 shows the firmware version number 1 14 Note Your TruAngle may display a different firmware version number 2 Upon release of the buttons the LCD should look like Figure 9 prompting you to index the encoder Page 9 For future reference make note here of the firmware version number __________ Turn the LCD Backlight On or Off When working in low light conditions you may f...

Страница 11: ...e index the encoder and then short press the OK button to enter the Measurement Mode 2 Short press the BS button to activate the Backsight Mode and start updating the display The display flashes during this process 3 Rotate the TruAngle until the desired Backsight value is displayed Use the Fine Adjust wheel to assist in displaying the correct value Note that some hundredths values will not displa...

Страница 12: ... a measurement is recorded the TruAngle will also record the current angle measurement and display that angle measurement on the LCD The measurement display and backlight will flash three times Then the angle measurement will display steady The flash indicates the measurements are being downloaded through the data serial port automatically The TruAngle is ready for a new angle measurement 3 Repeat...

Страница 13: ...ed by NMEA 0183 the CR400 format does not respond to unrecognized header formats malformed messages or messages with invalid checksums Laser Settings Impulse 200 and 200 LR Select the CR400 message format and the Auto Download option The Impulse will not communicate with the TruAngle if the IP200 download format is active TruPulse Series The CR400 message format with Auto Download is only option o...

Страница 14: ...haracter are intercepted and acted upon by TruAngle TruPulse Series and TruSpeed Sx Lasers Only Serial commands can be sent to the laser via a PC while cabled to the TruAngle For example the GO command will fire the laser capture a measurement and then download the serial data string from the laser to TruAngle capture the angle measurement and then download the complete serial data string to the P...

Страница 15: ...Command PWR CR LF where message identifier PWR refers to Power Down the TruAngle CR carriage return LF line feed Example Reply OK CR LF Time Out Interval The factory default Time Out Interval is 60 minutes Page 8 This command allows you to change the Time Out interval Get TO CR LF Reply TO n CR LF Set TO n CR LF Instrument Reply OK CR LF where message identifier TO refers to the Time Out Interval ...

Страница 16: ...ument can be aimed at target 3 Locked angle is set as current angle display flashes 3 times and normal operation resumes 4 Cancels Backsight operation after a BS 1 or BS 2 command and returns the instrument to normal operation CR carriage return LF line feed Example BS 1 CR LF Turns on the backlight TruPulse Series and TruSpeed Sx Only Serial commands can be sent to the TruPulse series and TruSpee...

Страница 17: ...ized character etc Try to enter command again 2 Memory checksum failure If you see this code try cycling the power OFF and ON and then repeat the measurement If the error persists please contact Laser Technology Inc for assistance 3 Instrument is in Index Mode Rotate the unit to set the index Page 9 4 Instrument is in Backsight Mode Set the non zero backsight or cancel Backsight Mode CR carriage r...

Страница 18: ...ion instrument and should be handled with care It will withstand a reasonable drop shock If the encoder is subjected to a severe mechanical shock you should power on the instrument and index the encoder Page 9 Cleaning and Storage Clean the TruAngle after each use Before returning it to its case check for the following items Excess moisture Towel off excess moisture and air dry the instrument at r...

Страница 19: ...ou are using and does not rotate To aid in this tighten down the friction lock so the entire unit will not rotate When turning the unit the gears seem to grind Loosen the friction lock until it moves smoothly After referencing the TruAngle the data strings are not being output The display is updating when rotated but now it is flashing The ZERO BS button was inadvertently pressed Cycle the Power O...

Страница 20: ... 122 F 30 to 50 C Storage 40 to 176 F 40 to 80 C Size Height to top of bubble level 5 6 in 14 2 cm Diameter 4 55 in 11 6 cm Width with tall side brackets 5 65 in 14 4 cm Width with short side brackets 5 41 in 13 7 cm Short Side Bracket total height 10 43 in 26 5 cm Tall Side Bracket total height 15 08 in 38 3 cm Weight 2 25 lbs 1 02 kg Weight includes batteries does not include side brackets Const...

Страница 21: ...uires registration that registration must also be completed to benefit from this limited warranty Software reproduction is forbidden LTI has no obligation to modify or upgrade a product once sold Limitation of Liability In no event will LTI be liable for damages including any lost profits lost savings or other incidental or consequential damages arising from the use or inability to use such produc...

Страница 22: ...noise 17 I Impulse 5 11 ind 7 17 indexing the encoder 9 instrument id 12 L LASER port 6 laser settings 11 LCD 2 16 M maintenance 16 measurement 10 measurement units 18 moisture 16 moisture protection 16 N NMEA compliance 11 non zero backsight 9 removing 9 10 O OFF button 7 OK button 7 ON button 7 P power down 13 power supply 18 powering OFF 8 ON 7 precautions 2 R range 18 remote trigger 11 report ...

Отзывы: