background image

WAL-TL-2X12W-C-SP

24 Watt LED Signal Stack Spot Light

Dual Color LED Traffic Light - NEMA 4X - Corrosion Resistant

Instruction Manual

Thank you for your purchase of the Larson Electronics WAL-TL-2X12W-C-SP LED Signal Stack Light. 

IMPORTANT

 

READ CAREFULLY BEFORE INSTALLING THIS FIXTURE. SAVE THESE INSTRUCTIONS FOR FUTURE 

REFERENCE.  THE 

WAL-TL-2X12W-C-SP

  MUST  BE  WIRED  IN  ACCORDANCE  WITH  NATIONAL  ELECTRICAL 

CODE AND ALL APPLICABLE LOCAL CODES. PROPER GROUNDING IS REQUIRED FOR SAFETY.  

WE STRONGLY ENCOURAGE ONLY A LICENSED ELECTRICIAN INSTALL, OPERATE AND MAINTAIN THIS 

PRODUCT. IF YOU ARE NOT QUALIFIED OR UNFAMILIAR WITH ANY ASPECT  OF THIS INSTRUCTION SHEET, 

CONSULT AN ELECTRICIAN. THERE ARE NO SERVICEABLE PARTS INSIDE. 

WARNING:

 

MAKE SURE POWER IS TURNED 

OFF

 BEFORE STARTING THE 

INSTALLATION OR PERFORMING ANY MAINTENANCE.

 

 

RISK OF FIRE/ELECTRIC SHOCK –

 

DISCONNECT POWER AT BREAKER BEFORE INSTALLING OR SERVICING.

 

RISK OF PERSONAL INJURY –

 

FIXTURE MAY BECOME UNSTABLE OR DAMAGED IF NOT INSTALLED PROPERLY. 

RISK OF BURN –

 

ALLOW FIXTURE TO COOL BEFORE SERVICING. 

The WAL-TL-2X12W-C-SP LED traffic light is an ideal indicator lighting solution for for industrial, marine, and 

manufacturing facilities. The light housings are fully sealed within a waterproof aluminum chassis fixture that features a 

very small profile for easy and unobtrusive mounting in tight and space limited areas. The mounting plate is also made 

from aluminum and can be custom built to customer specifications. This multi-colored indicator light provides color output 

as chosen when ordering, has a 50,000 hour operational life, and is available in 120-277 VAC. We also offer a 12/24 VDC 

configuration for low voltage operation.

INSTALLATION 

We strongly recommend only a licensed electrician install this product.

WARNING: 

Make sure power is disconnected prior to installing.

This fixture must be mounted to a 

flat 

surface that can structurally support the load. 

M

ounting holes are predrilled into the side

 flanges

 of the stack light back plate. 

Choose mounting location, lift unit into place, and drive mounting screws through the 

pre-drilled mounting holes in the side flanges. It may be necessary to have two 

people complete this installation.

 

WIRING

We strongly encourage only a licensed electrician install this product,

 in all 

locations, especially in outdoor areas where weatherproofing may be required. 

Warning:

 

Check product label for correct input voltage! 

Secure each pair of wires according to the wiring diagram shipped with your unit. 

Utilize a junction box or similar device and take precautionary steps for weather-

proofing all connections if installed in a location where water may come in contact 

with the unit. Ensure the unit is properly grounded and that wiring is done according 

to all local and national electrical/building codes. 

Larson Electronics, LLC

 

Phone: (877) 348-9680

 Fax: (903) 498-3364 

  www.larsonelectronics.com 

1

 of 

2

 

Note: 

Line-in power is connected to the wires labeled "120-277V Inbound". The lights are then individually wired via the 

wires labeled 9-32V and the corresponding color (this will be the + for the light it corresponds to), which is then mated with 

the 9-32V DCP wire to power the light

 (this will be the - to complete the connection for each light)

. Final configuration and 

controller or switch setup is left to the installer. Lights can be setup to operate independently, or separately, depending on 

the controller or switch being used. 