Func
Code
Name
Range
Min
Unit
Factory
Default
Modify
P4.00
Input terminal
X1 function
selection
24 Running command control mode
selection 2
25 Swing frequency selection
26 Swing frequency running reset
27 Close loop invalid
28 Simple PLC pause running
command
29 PLC invalid
30 PLC Reset in stopping state
31 Freq. switch to CI
32 Counter trig signal input
33 Counter clear input
34 External interrupt input
35 Pulse freq. input (only valid for
X6)
36 Fire mode
:
:
:
:
:
:
:
:
:
:
:
:
:
0.1
20.0
○
P4.01
Input terminal
X2 function
selection
Ditto
1
0
×
P4.02
Input terminal
X3 function
selection
Ditto
1
0
×
P4.03
Input terminal
X4 function
selection
Ditto
1
0
×
P4.04
Input terminal
X5 function
selection
Ditto
1
0
×
P4.05
Input terminal
X6 function
selection
Ditto
1
0
×
P4.06
Input terminal
X7 function
selection
Ditto
1
0
×
P4.07
Input terminal
X8 function
selection
Ditto
1
0
×
P4.08
FWD/REV
running
mode selection
0 2-wire control mode 1
1 2-wire control mode 2
2 3-wire control mode 1
3 3-wire control mode 2
:
:
:
:
1
0
×
P4.09
UP/DN Rate
0.01
-
99.99Hz/s
0.01
1.00
Hz/s
○
Larson Electronics, LLC
Phone:
Fax: (903) 498-3364
www.larsonelectronics.com
25
of
52
VFD-1P-220.240-1HP-7A-DCM
(877) 348-9680