LEDP5W-12LT
Rechargeable LED Light Tower
Extends 3 to 8 Feet - 12, 5-Watt LEDs - 5 Hour Runtime
Instruction Manual
IMPORTANT
READ CAREFULLY BEFORE INSTALLING THIS FIXTURE. SAVE THESE INSTRUCTIONS FOR FUTURE
REFERENCE. THE
LEDP5W-12LT
MUST BE WIRED IN ACCORDANCE WITH NATIONAL ELECTRICAL CODE AND
ALL APPLICABLE LOCAL CODES. PROPER GROUNDING IS REQUIRED FOR SAFETY.
WE STRONGLY ENCOURAGE ONLY A LICENSED ELECTRICIAN INSTALL, OPERATE AND MAINTAIN THIS
PRODUCT. IF YOU ARE NOT QUALIFIED OR UNFAMILIAR WITH ANY ASPECT OF THIS INSTRUCTION SHEET,
CONSULT AN ELECTRICIAN. THERE ARE NO SERVICEABLE PARTS INSIDE.
WARNING:
MAKE SURE POWER IS TURNED
OFF
BEFORE STARTING THE
INSTALLATION OR PERFORMING ANY MAINTENANCE.
RISK OF FIRE/ELECTRIC SHOCK –
DISCONNECT POWER AT BREAKER BEFORE INSTALLING OR SERVICING.
RISK OF PERSONAL INJURY –
FIXTURE MAY BECOME UNSTABLE OR DAMAGED IF NOT INSTALLED PROPERLY.
RISK OF BURN –
ALLOW FIXTURE TO COOL BEFORE SERVICING.
Never place spotlight face down when light is on. Doing so could burn/ignite surfaces such as seats, carpeting, etc. and
cause major property damage. Always turn spotlight off when not in use.
Avoid direct eye exposure the light source when light is on.
DO NOT
shine light into the face of someone else.
DO NOT
touch lens of light when on or recently on. The lens/cooling fins will be hot after long periods.
DO NOT
allow children to handle or operate this light.
DO NOT
use this product for other than its intended use.
DO NOT
operate in close proximity of combustible or flammable materials.
DO NOT
attempt to operate this light if cord, plug, battery, lens or any part of the light is damaged or corroded.
The LEDP5W-12LT LED light tower is a fully portable and rechargeable unit and produces a wide flood or far reaching
spot light ideal for use on construction sites and emergency scenes. This light tower offers a long list of features including
versatile power and recharging options and provides a highly portable lighting solution that is ideal for use as flagger
illumination, utility lighting, underground illumination, and anywhere a versatile, lightweight, rechargeable LED light tower
is needed.
Larson Electronics, LLC
Phone: (877) 348-9680
Fax: (903) 498-3364
www.larsonelectronics.com
1
of
2
SETUP
1.
Charge unit for 24 hours when new and every three months thereafter to maintain a full charge
(Charge monthly in hot weather)
2.
Do not charge or use this light in hazardous location
3.
Extend retractable legs if necessary for uneven terrain
4.
Extend aluminum pole to desired height and tighten each pole section into position
OPERATION
1.
Single head light will operate over 40 hours on a full charge
2.
Dual head light will operate over 20 hours on a full charge
3.
The power port provided can be used to operate a cell phone, a laptop computer, or any of
Larson Electronics’ handheld light with cigarette plug. The power port can be used a quick
charge inlet for the light from an automobile’s 12-volt power port.
4.
Order Larson Electronics’ power port duel end cable for connection from vehicle to light.
1.
Press the
RED
push button momentarily to turn the gauge on:
2.
The
GREEN
shaded indicator bar indicates the unit is capable of normal operation.
3.
The
YELLOW
shaded indicator bar indicates the unit needs to be recharged.
4.
The
RED
shaded indicator bar indicates the unit must be recharged before use.
BATTERY STATUS GAUGE