4.
Additional clamps may be used, if needed to secure power cable to piling. Prevent abrasion by routing cable to
side of piling away from vessel access. Do not over tighten the clamp on the cable where it can cut or pinch the
cable.
Power Unit Installation
Note:
This fixture is suitable for installation in wet locations. It is not intended to be submerged or exposed to repeated
direct wave action.
1.
Determine the mounting location of the Power Unit ensuring all underwater light cables reach the supply and are
routed to prevent abrasion from vessels or other moving components.
2.
With provided stainless steel screws, attach power unit to suitable structure at least 1 foot above ground level with
the high and low voltage cables pointing down.
NOTE:
Do not energize transformer until installation of system is
complete.
Electrical Connection
Notes:
Fixture may be switched with a timer, photo detector, or toggle switch prior to the receptacle.
DO NOT connect power unit to a dimmer.
Use approved outdoor (While in use) weatherproof receptacle cover to protect cord and outlet from weather while
plugged in.
Provide electrical service according to the electric code for your specific application from a suitable ground fault
circuit interrupter (GFCI) receptacle.
1.
All high voltage components in the fixture are prewired so electrical connection only needs to be made on the
secondary (24VDC low voltage) side of the power supply.
NOTE:
the power unit is rated for 110W max load. Do
not connect more than 4 dock lights to this supply.
2.
Split low voltage cable back approximately 3 inches and strip conductors back 3/8 inch if not already done so.
3.
Insert low voltage cables into cable glands on the bottom of the power unit. Tighten cable glands until the cables
are secure.
4.
Connect all red wires together by lifting orange levers on connector and inserting conductor so that bare metal is
not exposed. Fold levers down once conductor is inserted. Check for secure connection.
Complete the same procedure on black low voltage wires. Note: Low voltage cables must remain in the bottom of
the power unit enclosure and must not be routed near high voltage splice.
Operation
An abrupt OFF/ON toggle of your switch allows the dock light to transition through various light output modes. Light will
cycle through all available colors within the first 20 seconds, (including white). A brief OFF/ON toggle will allow the user to
select any discrete color during the cycle. After 20 seconds without interruption, the light will continue a full color cycle