OF

TITLE

DRAWN BY

DATE

CHECKED BY

SHEET #

LARSON

ELECTRONICS

9419 E US HWY 175,

KEMP, TX 75143

DRAWING #

REV

EXP-MTSTR-DOL-3P-480V-5HP-5A

J.Maldonado

05-25-2023

S.Desai

1

1

101

A

101.01

101.02

101.03

101.04

101.05

101.06

101.07

101.08

101.09

101.10

101.11

101.12

101.13

101.14

101.15

101.16

101.17

101.18

101.19

101.20

101.21

101.22

101.23

101.24

101.25

101.26

101.27

101.28

101.29

101.30

7A MOTOR CIRCUIT PROTECTOR

CB1-101.17

W/ OVERLOAD PROTECTION

3P CONTACTOR

CR1-101.05

480VAC L1

480VAC L2

480VAC L3

480VAC T1

480VAC T2

480VAC T3

COIL 110/120VAC L

COIL 110/120VAC N

NC

NO 101.08,101.15,101.17,101.19

110V@50HZ, 120V@60HZ

CONTACTOR COIL VOLTAGE

CR1-101.05

GND

GRN_14AWG

YEL_14AWG

ORG_14AWG

BRN_14AWG

BRN_14AWG

ORG_14AWG

YEL_14AWG

BRN_14AWG

ORG_14AWG

YEL_14AWG

WHT_18AWG

EXP PROOF ENCLOSURE

TAGS

QTY

CATALOG

DESCRIPTION

CB1-101.11

1

UNV00018792

Explosion Proof Combination Motor Starter - Class I, II, III

- 5HP, 480V Rated 3PH - NEMA 4, 4X

RESET 120VAC L

RESET 120VAC N

PB1-101.14

N.O. RESET

MOMENTARY BUTTON

REMOTE RESET MODULE

WHT_18AWG

BLK_18AWG

BLK_18AWG

MOMENTARY BUTTON

N.C. STOP

PB1-101.05

WHT_18AWG

WHT_18AWG

BLK_18AWG

BLK_18AWG

PB1-101.05A

N.O. START

MOMENTARY BUTTON

AUXILIARY CONTACT

CR1-101.05

PLEASE NOTE:

N.C. STOP AND N.O. START BUTTONS ARE NOT INCLUDED

OF OVERLOAD

N.C. CONTACT

CR

BLK_18AWG

BLK_18AWG

IF N.C. STOP AND N.O. START BUTTONS ARE

NOT BEING INSTALLED, CONNECT 120VAC

DIRECTLY TO CONTACTOR COIL WHILE USING

N.C. CONTACT OF OVERLOAD

Содержание EXP-MTSTR-DOL-3P-480V-5HP-5A

Страница 1: ... EXP MTSTR DOL 3P 480V 5HP 5A Explosion Proof Combination Starter is designed for surface mounting applications facilitated by slotted mounting feet on the rear of the enclosure The enclosure can be mounted to any flat surface capable of supporting the load Lift the enclosure into place and drive heavy duty mounting screws or bolts through the mounting slots and surface Be sure enclosure is mounte...

Страница 2: ...the equipment In the event of an overload on the equipment side the thermal circuit protector inside the enclosure will trip cutting power to the equipment and protecting it from damage To reset the circuit protector verify the load on the circuit protector is not beyond maximum rating and press the reset button on the front of the starter unit to restore power to equipment DO NOT OPEN THE UNIT WI...

Страница 3: ...H 1 G F E 3 2 4 D C B A 1 2 3 4 5 7 6 8 H G F E 5 6 7 D C B 8 A REV DESCRIPTION DATE PRODUCTION RELEASE 05 25 2023 EXP MTSTR DOL 3P 480V 5HP 5A A ...

Страница 4: ... 101 17 101 19 110V 50HZ 120V 60HZ CONTACTOR COIL VOLTAGE CR1 101 05 GND GRN_14AWG YEL_14AWG ORG_14AWG BRN_14AWG BRN_14AWG ORG_14AWG YEL_14AWG BRN_14AWG ORG_14AWG YEL_14AWG WHT_18AWG EXP PROOF ENCLOSURE TAGS QTY CATALOG DESCRIPTION CB1 101 11 1 UNV00018792 Explosion Proof Combination Motor Starter Class I II III 5HP 480V Rated 3PH NEMA 4 4X RESET 120VAC L RESET 120VAC N PB1 101 14 N O RESET MOMENT...

Отзывы: