WORKING
Hold the cock (G1) slightly open, thus preventing
the product from returning to the atomization
air delivery circuit and clogging the gun and
the air delivery hose.
Insert the block (G2) to allow the air to escape
when fi lling the delivery hose with product for
the fi rst time.
Before starting the pump, it is important to send
a small amount of atomization air to the gun.
•
After introducing the product into the tank (
F13
), close the
product delivery valve (
F14
) on the gun and open the recir-
culation valve (
F15
).
•
Turn the pressure adjustment knob (
F11
) clockwise to start
the pump.
•
If the product has properly been mixed, you should see it
come out of the recirculation hose (
F16
). If the product does
not recirculate it means that it is too dense and it must be
further diluted until obtaining the correct recirculation fl ow;
let the product recirculate for a short time. At this point, the
machine is ready to start working.