G1
G2
G6
G3
G5
G4
B
G7
A
Ed. 002 - 01/2017
G
WORKING
• Activate the motor start control using the the self-coiling
starter (
G2
).
SETUP PROCEDURE
• Use the tooling after performing all the
SETTING UP
ope-
rations above described.
• Make sure that all the levers are in the “
DISENGAGED
”
position.
• Check that there is enough unleaded petrol.
Turn fuel (
G1
) knob to
“ON”
.
• Close the re-circulation valve (
G3
).
• Open the taps (
G5
) and (
G6
) of the guns.
• Turn the pressure adjustment handle (
G4
) to the necessary
operating value (120 ÷ 190 bar).
• Release the brake on the rear wheel using the lever (
G7
),
in order to be able to move the machine more easily and
accurately.
A = Disconnected block
B = Connected block
• Open the re-circulation valve (
G3
).
• Turn pressure regulating knob (
G4
) clockwise a little so
that the machine idles.
• Visually check that the product starts to re-circulate within
the tank.
www.larius.eu
DRAGON LINER