LARIUS 4
12
I
prOBLeMs aND sOLUtION
solution
Cause
problem
•
the pump does not start up
•
the pump has accelerated opera-
tion and does not suck the product
•
the pump stalled continuously
•
Feed air not sufficient;
•
Outlet product line clogged;
•
Clogged product intake line;
• The membrane has ruptured;
• The drive valve has locked;
•
There is no product;
•
The pump sucks air;
•
The “balls” do not close perfectly;
•
The feed air is insufficient.
• Check the air supply line. Increase
the feed hose diameter;
• Clean. Detach the product outfeed
hose power the pump at minimum
pressure and check if the pump
starts without the outfeed hose;
• Check the hose and the intake filter.
Clean;
• Replace the membrane;
• Press the reset buttons located at
the sides of the valve;
• Add the product;
• Check the suction pipe;
• Remove and clean and/or replace
the balls and ball seats;
• Check the air supply line. Increase
the feed hose diameter;
• Check that the parts of the air feed
circuit guarantee a sufficient flow
rate (the quick-couplings cause
pressure drops).
always close the compressed air supply and release the pressure in the system before checking or replacing
the pump parts.