44428235
Assembly instruction
Valid from
28.07.2021
EPIC
®
SOLAR 4PLUS
Document: L44428235EN
Version: 03
Page 5 of 8
We reserve all rights according to DIN ISO 16016.
Mounting of EPIC
®
SOLAR 4PLUS
Analysing the cable
Determining the conductor cross section
Determining the outer diameter
Article
Number
Designation
Cross section
in [mm²]
Cable clamping
range d in [mm]
Stripping
Length L [mm]
Rated
Current [A]
EPIC
®
SOLAR 4PLUS Female Connector, field mountable, including Contacts
44428236
EPIC
®
SOLAR 4PLUS F 4 mm² -
6 mm²
4 – 6
5,2 - 7,1
8
30
44428238
EPIC
®
SOLAR 4PLUS F 10 mm²
10
5,2 – 7,1
12
30
EPIC
®
SOLAR 4PLUS Male Connector, field mountable, including Contacts
44428235
EPIC
®
SOLAR 4PLUS M 4 mm² -
6mm²
4 – 6
5,2 - 7,1
8
30
44428237
EPIC
®
SOLAR 4PLUS M 10 mm²
10
5,2 – 7,1
12
30
Preparing the cable
Cut the cable cleanly - the strands must not have any oxidation or contamination.
Stripping the cable
Stripping length: depending on the table (see table above!).
The insulation must be removed clean and competed. No stranded wires may be cut off