44428235 

Assembly instruction

 

 

Valid from 

28.07.2021

 

EPIC

®

 SOLAR 4PLUS 

 

Document: L44428235EN 
Version: 03 

Page 8 of 8 

We reserve all rights according to DIN ISO 16016.

 

 

Laying the cable 

The cables must be firmly laid in the photovoltaic system, securely fastened and the minimum 
bending radius must not be undercut. The cable must be led straight out of the connector at 
least L=50 mm. The bending radius R

min

 must be at least 10x cable diameter. 

  

 

 
 
 
 
 
 
 

U.I. Lapp GmbH 
Schulze- Delitzsch- Straße 25 •D-70565 Stuttgart 
Tel.: +49 (0) 711 7838-01 
Fax.: + 49 (0) 711 7838 2640 

www.lappkabel.de

 

[email protected] 

 

Содержание 44428235

Страница 1: ...ble 5 Stripping the cable 5 Crimping the contacts 6 Mounting 7 Connecting and Disconnecting 7 Laying the cable 8 Trademark on the Product EPIC Scope of delivery The Connector EPIC SOLAR 4PLUS is deliv...

Страница 2: ...ions According to IEC 62582 2014 Rated Voltage 1 500V DC Rated Current 30A 4 0 mm 30A 6 0 mm 30 A 10 mm Rated impulse withstand voltage 16 kV Rated temperature 40 C 85 C Upper limit of Temperature 105...

Страница 3: ...U 1 0 1 0 kV DC 1 5 kV Max Voltage DC 1 8 kV Conductor Earth System without Earth connection Mated connectors are IP68 protected 1m 10h Continuous ooperation under water e g water on the roof skin of...

Страница 4: ...LAPP Universal Strip Solar Item number 21920120 EPIC SOLAR Mounting Tool is not necessary Two 19 mm open end wrenches are also working Crimping Tool Note To comply the tested quality it s necessary t...

Страница 5: ...SOLAR 4PLUS Female Connector field mountable including Contacts 44428236 EPIC SOLAR 4PLUS F 4 mm 6 mm 4 6 5 2 7 1 8 30 44428238 EPIC SOLAR 4PLUS F 10 mm 10 5 2 7 1 12 30 EPIC SOLAR 4PLUS Male Connect...

Страница 6: ...letely into the crimp area of the contact The cable is pushed forward until the insulation strikes the crimp receptacle of the contact In this way a supernatant of at least 2 mm is ensured Completely...

Страница 7: ...Turn cap nut hand tight 4 5 Nm finished Spanner size 19 EPIC SOLAR 4PLUS F Connecting and Disconnecting Before plugging in check the plugging area for possible soiling and clean it if necessary Especi...

Страница 8: ...es must be firmly laid in the photovoltaic system securely fastened and the minimum bending radius must not be undercut The cable must be led straight out of the connector at least L 50 mm The bending...

Отзывы: