9: Setup Mode: Advanced Settings
XPress™ DR Industrial Device Server User Guide
59
SNMP Community Name
This option allows you to change the SNMP Community Name on the unit. This allows for ease of
management, and possibly some security. If someone tries to violate security but doesn’t know
what community to connect to, that person will be unable to get the SNMP community information
from the unit. The name is a string of 1 to 13 characters plus a null-terminator (14 bytes total).
The default setting is
public
.
SNMP Community Name (public):
Disable Telnet Setup
This setting defaults to the
N
(No) option. The
Y
(Yes) option disables access to this
Configuration Menu by Telnet (port 9999). It only allows access via the Web pages and the serial
port of the unit.
Disable Telnet Setup (N) ?
Disable TFTP Firmware Upgrade
This setting defaults to the
N
(No) option. The
Y
(Yes) option disables the use of TFTP to perform
network firmware upgrades. With this option, firmware upgrades can be performed only by using
a *.hex file over the serial port of the unit. See
Disable TFTP Firmware Update (N) ?
Disable Port 77FE (Hex)
Port 77FE is a setting that allows DeviceInstaller, Web Pages, and custom programs to configure
the unit remotely. You may wish to disable this capability for security purposes. For more
information about remote configuration, see the
Lantronix Embedded Integration Kit User Guide
at the Lantronix Web site
Disable Port 77FEh (N) ?
The default setting is the
N
(No) option, which enables remote configuration. You can configure
the unit by using DeviceInstaller, Web pages, Telnet, or serial configuration. The
Y
(Yes) option
disables remote configuration and Web pages.
Note:
The Yes option disables many of the GUI tools for configuring the device server, including
the embedded Web Page Configuration tool.
77FEh Access Mode
Configuring this setting is available if port 77FE is enabled. This option will not be listed if port
77FE is disabled.
Set 0 for Read & Write mode, and 1 for Read Only mode. Default value of this setting is Read-
Write(0).
If access mode is Read-only, then read operation can be done through port 77FE, if Read-Write
access is selected, then both read and write of data can be done through port 77FE.
77FEh Access Mode (0=Read & Write, 1=Read Only): (0) ? _
Disable Web Server
This setting defaults to the
N
(option). The
Y
(Yes) option disables the use of the Web Page
Configuration tool that is built into the unit.
Disable Web Server (N) ?