5: Configuration Using Web Manager
XPress™ DR Industrial Device Server User Guide
38
2. Update the following:
Connect Protocol
Protocol
From the drop-down menu, select
TCP.
Connect Mode: Passive Connection
Accept Incoming
Select
Yes
to accept incoming connections. The default setting is
Yes.
Password Required
Determines whether a password is required for an incoming passive
connection. This field is not available when a password is set for Telnet
mode. The default setting is
No
.
Password
If
Password Required
was set to
Yes
, enter the password for passive
connections.
Modem Escape Sequence
Pass Through
Disable or enable the XPress device server’s ability to send the escape
sequence. The default is
Yes
(send the escape sequence).
Connect Mode: Active Connection
Active Connect
Select
None
(default)
to disable
Active Connect
. Otherwise, indicate
the connection type from the drop-down list:
With Any Character:
Attempts to connect when any character is
received from the serial port.
With Active Mdm Ctrl In:
Accepts external connection requests
only when the Modem Control In input is asserted.
With Start Character:
Attempts to connect when it receives a
specific start character from the serial port. The default start
character is carriage return.
Manual Connection:
Attempts to connect when directed by a
command string received from the serial port.
Auto Start:
Automatically connects to the remote IP address and
port after booting up.
Start Character
If Active Connect is set to
With Start Character
, enter the start
character in this field. The default setting is
0D
.
Modem Mode
Indicates the on-screen response type when in Modem Mode (if
Modem
Mode
is enabled). The default setting is
None
.
Show IP Address After RING
Indicates whether to display the remote IP address upon connection.
The default setting is
Yes
.
Endpoint Configuration
Local Port
Enter the local port number.
Auto increment for Local Port
for active connect
Select to auto-increment the local port number for new outgoing
connections. The range of auto-incremented port numbers is
50,000
to
59,999
and loops back to the beginning when the maximum range is
reached. Disabled by default.