Configuration via Serial Mode or Telnet Port
WiPort™ User Guide
45
Manual Connection
Attempts to connect when directed by a command string
received from the serial port. The first character of the command
string must be a
C
(ASCII 0x43), and the last character must be
either a carriage return (ASCII 0x0D) or a line feed (0x0A). No
blanks or space characters may be in the command string.
Between the first and last command string characters must be a
full or partial destination IP address and can include a
destination port number.
The IP address must be in standard dot-decimal notation and
may be a partial address, representing the least significant 1, 2,
or 3 bytes of the remote IP address. The period is required
between each pair of IP address numbers.
If present, the port number must follow the IP address, must be
presented as a decimal number in the range 1-65535, and must
be preceded by a forward slash (ASCII 0x2F). The slash
separates the IP address and the port number. If you omit the
port number from a command string, the internally stored remote
port number starts a connection.
If a partial IP address is presented in a command string, it is
interpreted to be the least significant bytes of the IP address and
uses the internally stored remote IP address to provide the most
significant bytes of the IP address. If the IP address entered is
0.0.0.0/0, the device server enters Monitor Mode.
For example, if the remote IP address already configured in the
unit is 129.1.2.3, then an example command string would be
C3/7. (This would connect to 129.1.2.3 and port 7.) You may
also use a different ending for the connection string. For
example, C50.1/23 would connect you to 129.1.50.1 and port 23.
Table 5-7. Manual Connection Address Example
Command String
Result if remote IP is 129.1.2.3 and remote port is 1234
C121.2.4.5/1
Complete override; connection is started with host 121.2.4.5, port 1
C5
Connects to 129.1.2.5, port 1234
C28.10/12
Connects to 129.1.28.10, port 12
C0.0.0.0/0
Connects to 129.1.28.10, port 12; enters Monitor Mode
Autostart (Automatic
Connection)
The unit automatically attempts a connection to the remote IP
address and port after booting up.