This chapter discusses how you can diagnose and fix errors quickly without having to
contact a dealer or Lantronix. It helps to connect a terminal to the serial port while
diagnosing an error to view summary messages that may be displayed. When
troubleshooting, always ensure that the physical connections (power cable, network
cable, and serial cable) are secure.
Note:
Some unexplained errors might be caused by duplicate IP addresses on the
network. Make sure that your unit's IP address is unique.
When troubleshooting the following problems, make sure that the WiBox is powered
up. Confirm that you are using a good network connection.
Problems and Error Messages
Problem/Message
Reason
Solution
When you issue the
ARP –S
command in Windows,
The
ARP entry addition failed: 5
message displays.
Your currently logged-in user
does not have the right to use
this command on this PC.
Have someone from your IT
department log you in with
sufficient rights.
When you attempt to assign an
IP address to the unit by the
ARP method and Telnet to the
device server through port 1,
the connection fails.
When you Telnet to port 1 on the
device server, you are only
assigning a temporary IP
address. When you Telnet into
port 9999 and do not press
Enter
quickly, the device server
reboots, causing it to lose the IP
address.
Telnet back to Port 1. Wait for it to
fail, then Telnet to port 9999
again. Make sure you press
Enter
within 5 seconds.
When you Telnet to port 9999,
the
Press Enter to go into
Setup Mode
message displays.
However, nothing happens
when you press
Enter
, or your
connection is closed.
You did not press
Enter
quickly
enough. You only have 5
seconds to press
Enter
before
the connection is closed.
Telnet to port 9999 again, but
press
Enter
as soon as you see
the
Press Enter to go into Setup
Mode
message.
When you Telnet to port 1 to
assign an IP address to the
device server, the Telnet
window does not respond for a
long time.
You may have entered the
Ethernet address incorrectly with
the ARP command.
Confirm that the Ethernet address
that you entered with the ARP
command is correct. The Ethernet
address may only include
numbers 0-9 and letters A-F. In
Windows and usually in Unix, the
segments of the Ethernet address
are separated by dashes. In some
forms of Unix, the Ethernet
address is segmented with
colons.
Содержание WiBox
Страница 1: ...INSERT PICTURE HERE WiBox User Guide Part Number 900 351 Revision A June 2004 ...
Страница 8: ...Contents 8 WiBox User Guide ...
Страница 20: ...Installation 20 WiBox User Guide ...
Страница 42: ...Configuration via Serial Mode or Telnet Port 42 WiBox User Guide ...
Страница 56: ...Configuration Using Web Manager 56 WiBox User Guide ...
Страница 57: ......