14: Command Reference
SLB™ Branch Office Manager User Guide
239
slp outletcontrol state <on|off|cyclepower> [outlet <Outlet #>][tower
<A|B>]
Outlet # is 1-8 for SLP8 power manager and 1-16 for SLP16 power manager.
The
outletcontrol
parameters control individual outlets.
slp outletstate [outlet <Outlet #>]
The
outletstate
parameter shows the state of all outlets or a single outlet.
slp envmon
Displays the environmental status (e.g., temperature and humidity) of the SLP
power manager
.
slp infeedstatus
Displays the infeed status and load of the SLP
power manager
.
slp system
Provides system information for the SLP
power manager
.
sensorsoft lowtemp <Low Temperature in C.>
Sets the lowest temperature permitted for the port.
sensorsoft hightemp <High Temperature in C.>
Sets the hightest temperature permitted for the port.
sensorsoft lowhumidity <Low Humidity %>
Sets the lowest humidity pemitted for the port.
sensorsoft highhumidity <High Humidity %>
Sets the lowest humidity permitted for the port.
sensorsoft traps <enable|disable>
Enables or disables traps when specified conditions are met.
sensorsoft status
Displays the status of the port.
Description
Sends commands to (or control) a device connected to an SLB device port over the serial port.
Note:
Currently the only devices supported for this type of interaction are the SLP and Sensorsoft
devices.
Device Port Commands
set deviceport port
Syntax
set deviceport port <Device Port List or Name> <one or more device port
parameters>
Example:
set deviceport port 2-5,6,12,15-16 baud 2400
Parameters
auth <
pap
|chap>
banner <Banner Text>
baud <300-115200>
breakseq <1-10 Chars>