LED Troubleshooting

 

Symptom 

Possible Cause 

Suggested Solution 

System LED is Off 

The switch is not 
receiving power. 

1. Check if correct power cord is connected firmly to the switch and to 
the DC outlet socket.   
2. Perform power cycling the switch by unplugging and plugging the 
power cord back into the switch. 
3. If the LED is still off, try to plug the power cord into a different DC 
outlet socket to make sure correct DC source is supplied.   

Port (Left Side) 
Status LED is Off 

The port is not 
connected or the 
connection is not 
working. 

1. Check if the cable connector plug is firmly inserted and locked into 
the port at both the switch and the connected device. 
2. Make sure the connected device is up and running correctly. 
3. If the symptom still exists, try different cable or different port, in 
order to identify if it is related to the cable or specific port. 

Port (Right Side) 
Status LED is Off   

The port is not 
supplying power. 

1. Check if the cable connector plug is firmly inserted and locked into 
the port at both the switch and the connected device. 
2. Make sure the correct Ethernet cables are used. 
3. If the symptom still exists, try different cable or different port, in 
order to identify if it is related to the cable or specific port. 

PoE Modes and Compliance 

PoE Deployment Environments A and B 

IEEE802.3at-2009 defines two deployment environments in section 33.4.1: 

Environment A

: when both PSE and PD are located indoors, inside the same building. In this environment, there 

must be electrical isolation between the PoE circuitry and the data circuitry inside a PSE. Multi-port PSE’s can all 
share the same ground isolation. Environment A is therefore an indoor PSE –indoor PD environment (a.k.a. 
indoor/indoor).   

Environment B

: when the PSE and PD are not located in the same building. In this environment there needs to be 

electrical isolation between PoE and data, as well as between every port in a multi-port PSE. This isolation 
between ports requirement de facto determines a completely separate power supply per port, which makes 
multi-port PSE’s for outdoor PD deployment impractical. Environment B is therefore an indoor PSE-outdoor PD 
(a.k.a. indoor/outdoor) or outdoor PSE-outdoor PD (a.k.a. outdoor/outdoor) environment. 
This means only single-port PSE’s should normally be used when PD’s are deployed outdoors. In summary, the 
PD-PSE environment is one of these three combinations: 

1. PoE Source is indoor; PD is indoor (Env. A) 
2. PoE Source is indoor; PD is outdoor (Env. B) 
3. PoE Source is outdoor; PD is outdoor (Env. B) 

Option 3 is the most challenging environment since both the PD and PSE are installed outdoors.   

Содержание SISTP10 0-3-LRT Series

Страница 1: ...SISTP1040 342 LRT SISTP1040 382 LRT SISTP10x0 3xx LRT Series Unmanaged Hardened Gigabit Ethernet PoE Switches Install Guide Part Number 33733 Revision G April 2022 ...

Страница 2: ... Lantronix does not make and specifically disclaims all warranties of any kind express implied or otherwise regarding title non infringement fitness quality accuracy completeness usefulness suitability or performance of the information provided herein Lantronix shall have no liability whatsoever to any user for any damages losses and causes of action whether in contract or in tort or otherwise in ...

Страница 3: ...ntronix does so at their own risk and agrees to fully indemnify Lantronix for any damages that may result from such use or sale Attention this product like all electronic products uses semiconductors that can be damaged by ESD electrostatic discharge Always observe appropriate precautions when handling NOTE Emphasizes important information or calls your attention to related features or instruction...

Страница 4: ...tch on a DIN Rail 13 Install and Connect SFPs via Fiber Optic Cable 14 Connect PoE Ports via TP Copper Cable 14 PoE PoE Spec Comparison 15 IEEE 802 3bt Power Input Ripple and Noise Specification 15 Grounding 16 Power Supply Features and Specifications 17 Industrial Power Supply 25105 17 Industrial Power Supply 25104 18 Connecting to Power 19 Adjusting Power Supply Output Voltage V ADJ 19 LED Descr...

Страница 5: ... SFP webpage Note Information in this document is subject to change without notice Note that this manual provides links to third party web sites for which Lantronix is not responsible Key Features Slim type industrial switch IEEE 802 3af at Power over Ethernet IEEE 802 3az Energy Efficient Ethernet standard for green Ethernet application Flow Control Support Jumbo Frame up to 9K bytes Layer 2 wire...

Страница 6: ...ure Operating Humidity Altitude Fahrenheit Centigrade Fahrenheit Centigrade 5 to 95 non condensing Feet Meters 40 to 167 40 to 75 40 to 185 40 to 85 10000 3000 Dimensions Weights Mounting Model Dimension WxHxD Weight Mounting Type Millimeters Inches Kilograms Pounds SISTP1040 342 LRT 44x 135x 130 1 7x 5 3x 5 1 0 43 0 94 DIN rail Wall SISTP1040 382 LRT 44x 135x 130 1 7x 5 3x 5 1 0 46 1 01 DIN rail ...

Страница 7: ... and telecommunication ports 0 5KV Signal ports 0 25KV IEC 61000 4 5 SURGE Line to line 0 5KV Line to ground 1 0KV IEC 61000 4 6 CS Voltage Level 129 5 dB uV 3 0V IEC 61000 4 2 PFMF 1 A m A Regulatory Compliance EMI FCC Part 15 Class A Safety CE IEC62368 1 EN62368 1 CI D2 CI D2 Mechanical Stability Vibration IEC 60068 2 6 Shock IEC 60068 2 27 Freefall IEC 60068 2 32 MTBF Model MTBF Environment SIS...

Страница 8: ... TP Port x 8 1G SFP Port x 2 4 55 52 236 60 Full loading 60 minutes later 1G TP Port x 8 1G SFP Port x 2 4 55 52 236 60 2 DC 57V Input SISTP1040 382 LRT Status Operation Interface DC Current Consumption A DC Voltage V DC Power Consumption W Non loading None 0 07 57 3 99 Standby mode 1G TP Port x 8 1G SFP Port x 2 4 10 57 233 70 Full loading 60 minutes later 1G TP Port x 8 1G SFP Port x 2 4 10 57 2...

Страница 9: ...4 1G SFP Port x 2 2 29 52 119 08 Full loading 60 minutes later 1G TP Port x 4 1G SFP Port x 2 2 29 52 119 08 2 DC 57V Input SISTP1040 342 LRT Status Operation Interface DC Current Consumption A DC Voltage V DC Power Consumption W Non loading None 0 07 57 3 99 Standby mode 1G TP Port x 4 1G SFP Port x 2 2 08 57 118 56 Full loading 60 minutes later 1G TP Port x 4 1G SFP Port x 2 2 08 57 118 56 DC po...

Страница 10: ... LRT Install Guide 33733 Rev G https www lantronix com Page 10 of 31 Front Panel The SISTP1040 382 LRT front panel is shown below Back and Bottom Panels The SISTP1040 382 LRT back and bottom panels are shown below Back Bottom ...

Страница 11: ...Lantronix SISTP10x0 3xx LRT Install Guide 33733 Rev G https www lantronix com Page 11 of 31 RESET Button You can press the bottom panel RESET button to reboot the switch ...

Страница 12: ...k Start Guide Four rubber feet One Power Supply optional sold separately Contact your sales representative if any item is missing or damaged Switch Mounting Options The Switch can be installed in these ways Wall mounted DIN Rail Mounting the Switch on a Wall Optional 1 Attach the wall mounting plates to rear panel of the chassis Insert screws and tighten with a screwdriver to secure the plates 2 I...

Страница 13: ... rear panel of the chassis Insert screws and tighten with a screwdriver to secure the kit 2 Insert the upper lip of the DIN rail into the DIN rail mounting kit and press the switch towards the DIN rail until it snaps into place 3 Make sure that the switch is attached securely to DIN Rail Note Make all cable connections and perform grounding before connecting to power ...

Страница 14: ...aligning it with the internal installation guides Ensure that the SFP device is firmly seated against the internal mating connector 4 See the related SFP manual for operating information specific to your particular SFP model 5 Connect the other end of the cable to the appropriate far end Ethernet port Note After the cable is properly connected at both ends the Switch LED should be functional See L...

Страница 15: ...W 25 50 W Max Power from PSE 15 40 W 30 0 W Voltage Range at PSE 44 0 57 0 V 50 0 57 0 V Voltage Range at PD 37 0 57 0 V 42 5 57 0 V Max current 350 mA 600 mA per mode Max cable resistance 20 ohms Cat 3 12 5 ohms Cat 5 Power management 3 power class levels negotiated at 1st connection 4 power class levels negotiated at 1st connection or 0 1 W steps negotiated continuously Supported cabling Cat 3 a...

Страница 16: ...ating is 51 57 V DC each PoE port output is 30 W max Note Both the switch and Power Supply 25105 25104 must have their ground terminals connected to earth ground Caution Tying the output connection of the DC power supply to earth ground to create an earth referenced voltage power supply will violate the power supply isolation to earth ground requirements of IEEE 802 3af at bt If an earth grounded ...

Страница 17: ... 90 5 AC Current Typical 1 4A 115VAC 0 7A 230VAC Inrush Current Cold 35A 115VAC 70A 230VAC Leakage Current 1 0mA 240VAC Protection Overload 110 150 Overvoltage 56 65V Over Temperature 95ºC 5ºC Environment Operating Temp 25ºC 70ºC Storage Temp 40ºC 85ºC Operating Humidity 20 95 non condensing Features 91 High Efficiency 150 Peak Load Protected against Short Circuit Overload Over Voltage Overheating...

Страница 18: ...tion air cooling RoHS compliant MTBF 169 3 Khrs Dimensions mm 63W 125 2H 113 5D Weight 1 03Kg Standards Safety UL508 TUV EN60950 1 Vibration IEC60068 2 6 EMC Emission EN55022 CISPR22 Class B EN61000 3 2 EN61000 3 3 EMC Immunity EN61000 4 2 EN61000 4 3 EN61000 4 4 EN61000 4 5 EN61000 4 6 EN61000 4 8 EN61000 4 11 EN55024 EN61000 6 2 EN50082 2 EN61204 3 SEMI F47 GL Approved Description Mean Well SDR ...

Страница 19: ... Block into the switch before powering on 1 Insert the negative positive DC wires into the V and V terminals respectively 2 To keep the DC wires from pulling loose use a small flat blade screwdriver to tighten the wire clamp screws on the front of the Terminal Block connector 3 Plug the Power adapter plug into AC power at an appropriate AC outlet 4 Check the SYS LED If it is ON the power connectio...

Страница 20: ...m is ready Port Status LEDs indicate the current status of each port The front panel SYS and PWR LEDs are shown and described below See the PD device manual for its LED descriptions System and Power LEDs LED Color State Description SYS System Green On Off The switch is ready The switch is not ready PWR2 Green On Off The switch is powered on correctly The switch is not receiving power from Power 2 ...

Страница 21: ...onnected or it is not established a link to connected device RJ45 Ports Right Side Green On The port is enabled and supplying power to connected device Green Blinking An abnormal state such as overload status has been detected in the switch Off The port has no active network cable connected or it is not connected a PoE PD device SFP Ports Green On The port is enabled and established a link to conn...

Страница 22: ...en single color Off All Power Off On Switch FW Boot Complete Blinking System Booting Global P1 Input Power 1 Green Power 1 LED Green single color Off Power 1 Off On Power 1 On Global P2 Input Power 2 Green Power 2 LED Green single color Off Power 2 Off On Power 2 On TP RJ45 Ports 1 8 PoE Green Amber PoE on TP green amber bi color Off PoE is Off Green On PoE is On Amber On PoE Abnormal TP RJ45 Port...

Страница 23: ...ferent port in order to identify if it is related to the cable or specific port PoE Modes and Compliance PoE Deployment Environments A and B IEEE802 3at 2009 defines two deployment environments in section 33 4 1 Environment A when both PSE and PD are located indoors inside the same building In this environment there must be electrical isolation between the PoE circuitry and the data circuitry insi...

Страница 24: ...eroperability and connectivity issues Compliant PoE devices and compatible PoE devices are not held to the same 802 3af at standard 802 3af at compliant PDs fulfill the IEEE strict requirement to support both Mode A and Mode B power modes 802 3af at compatible PDs typically can provide power using only Mode B Typical PD Power Requirements 1 8 Watts Lantronix M GE ISW SFP 01 PD Class 1 Powered Devi...

Страница 25: ... If the trouble started after the PD was working what changed Did hardware or software change 4 Verify that the port is not shut down disabled or errored 5 Verify that the Ethernet cable from the PD to the switch port is good 6 Verify that the total cable length from the switch front panel to the connected PD is not more than 100 meters Some of the power from the switch port is dissipated in the c...

Страница 26: ...current threshold and disconnect power from the line This prevents excessive current from being delivered by the PoE port which could possibly result in damage to port level components 16 A variety of disturbances on the AC power line mains can cause odd PoE problems The power supplies in various switches and PDs can react uniquely to AC input disturbances AC disruption problems are usually tempor...

Страница 27: ...carries the CE Mark I the undersigned hereby declare that the equipment specified above conforms to the above Directive s and Standard s Place Minnetonka Minnesota Date July 28 2021 Signature Fathi Hakam Full Name Fathi Hakam Position Vice President of Engineering User Information Caution changes or modifications not expressly approved by the party responsible for compliance could void the user s ...

Страница 28: ... Caution Do not let optical fibers come into physical contact with any bare part of the body since they are fragile and difficult to detect and remove from the body Caution Do not bend any part of an optical fiber cable to a diameter that is smaller than the minimum permitted according to the manufacturer s specification usually about 65 mm or 2 5 in Warnings Warning Use of controls adjustments or...

Страница 29: ...ONCENTRATIONS IGNIFIABLES Electrical Safety Warnings Electrical Safety IMPORTANT This equipment must be installed in accordance with safety precautions Elektrische Sicherheit WICHTIG Für die Installation dieses Gerätes ist die Einhaltung von Sicherheitsvorkehrungen erforderlich Elektrisk sikkerhed VIGTIGT Dette udstyr skal enstallers i overensstemmelse med sikkerhedsadvarslerne Elektrische veiligh...

Страница 30: ..._________________________________________________________________ _______________________________________________________________________________________ Describe any action s already taken to resolve the problem e g changing switch mode rebooting etc ________________________________________________________________________________________ ___________________________________________________________...

Страница 31: ... 7535 Irvine Center Drive Suite100 Irvine CA 92618 USA Toll Free 800 526 8766 Phone 949 453 3990 Fax 949 453 3995 Technical Support Online https www lantronix com technical support Sales Offices For a current list of our domestic and international sales offices go to the Lantronix web site at www lantronix com about contact ...

Отзывы: