2 Installation
This section describes how to install the ION Management Module in an ION Chassis. This section also
describes the procedures to access the IONMM-232 through either a local serial interface (USB) or a
remote Ethernet connection (Telnet session or Web interface).
Installing the ION Management Module
The ION Management Module is to be installed only in a Lantronix ION chassis (ION001, ION002,
ION006, and ION219). For a complete list of ION platform products, go to the Lantronix website at
Note
: While the IONMM-232 can be hot-swapped in any slot in the chassis system, Lantronix
recommends that an organization use the same slot in every chassis, thereby normalizing any
maintenance procedures and techniques. Typically, this is done in slot 1 of the chassis as depicted in the
figure below.
Use the procedure below to install the IONMM-232 in the ION Chassis.
Wear a grounding device and observe electrostatic discharge precautions when installing the
IONMM-232 into the ION Chassis. Failure to observe this caution could result in damage to or failure of
the IONMM-232.
Figure 3: IONMM-232 Installation in 19-Slot Chassis