![Lantronix IONMM-232 Скачать руководство пользователя страница 14](http://html.mh-extra.com/html/lantronix/ionmm-232/ionmm-232_install-manual_675647014.webp)
Lantronix
IONMM-232 Install Guide
33725 Rev. B
14
Using an Ethernet Network
The IONMM-232 can be managed remotely through the Ethernet network via either a Telnet session or
a Web interface. Before this is possible you must set up the IP configuration for the IONMM-232.
Important
:
It is recommended that you initially set up the IP configuration through the serial interface
(USB connection). See “
Setting Up the IP Configuration
” section of the IONMM User Guide. Otherwise,
in order to communicate with the IONMM-232 across the network for the first time, you must change
the network settings (IP address, subnet mask and default gateway address) of your PC to coincide with
the defaults of the IONMM-232 (see “Appendix B” in the IONMM-232 User Guide).
Make note of the original settings for the PC as you will need them after setting the IP configuration for
the IONMM-232.
Starting a Telnet Session
The IONMM-232 can be controlled from a remote management station via a Telnet session over an
Ethernet connection. The IONMM-232 is controlled and configured through CLI commands. The
following describes the procedure to connect to and access the IONMM-232 via a Telnet session.
1.
Click
Start
.
2.
Select,
All Programs>Accessories
.
3.
Click
Command Prompt
. The command line window displays.
4.
At the command line type:
telnet
<xx> where xx = the IP address of the IONMM-232
5.
Press
Enter
. The login prompt displays.
Note
: If your system uses a security protocol (e.g., RADIUS, SSH, etc.), you must enter the login and
password required by that protocol.
6.
Type your login (the default is
ION
).
Note:
the login is case sensitive.
7.
Press
Enter
. The password prompt displays.
8.
Type your password (the default is
private
).
Note:
the password is case sensitive.
9.
Press
Enter
. The command line prompt displays.
You can now enter commands to set up the various configurations for the IONMM-232. For a
description of all available CLI commands see the
ION Systems CLI Reference Manual, 33461
.