Lantronix
ION002-AD User Guide
33612 Rev B
7
Powering the Chassis
CAUTION:
only one power input should be connected at any time.
To supply power to the ION002-AD chassis with the external AC/DC power supply (provided):
1. Connect the barrel connector on the supplied power adapter to the ION002-AD chassis’ power port (located on
the back of the chassis).
2a. Connect the power adapter plug (supplied) to AC power.
Note
: the power inputs are not redundant; only one
input can be used.
2b. For an optional DC power source, use the 2-wire terminal block. The input voltage on the 2-wire terminal block
is 21-60 VDC, polarity insensitive. This terminal block can be used if your installation site offers a low voltage DC
power source. See “Power via the DC INPUT (EuroBlock) Connector” below for more information.
3. Verify that the ION002-AD chassis is powered by observing the lit LED(s) on the installed slide-in card.
Power via the DC INPUT (EuroBlock) Connector
DC INPUT
:
21-60 VDC EuroBlock (Terminal Block). The procedures below describe how to remove the terminal
block, connect the Power wires to the Terminal Block, and then reinstall the terminal block and verify the Power
wire connections.
Removing the Terminal Block (TB)
1. Loosen the “2” mounting screws that attach the “primary” Terminal Block (TB) to the ION002-AD chassis.
2. Pull the TB from the ION002-AD chassis connector as shown below.
.