ContiPressureCheck™ System Integration into FOX3-2G/3G/4G Series
10
Example: SYS.eJ1939.TIRE_HEALTH>=0
SYS.eJ1939.TIRE_CPC_STAT_WEX<
comp
><
value
>
This event is generated whenever the contents of the
SYS.eJ1939.TIRE_CPC_STAT_WEX variable changes.
<
comp
> Compares the contents of this variable with the used
specified one and return a Boolean (True/False) representing the
result of the comparison. It can be set to =, !=, <,>, <= or>=.
<
value
> Specifies the value to be compared.
Example: SYS.eJ1939.TIRE_CPC_STAT_WEX>=0
SYS.eJ1939.TIRE_CPC_STAT_LEARN<
comp
><
value
>
This event is generated whenever the contents of the
SYS.eJ1939.TIRE_CPC_STAT_LEARN variable changes.
<
comp
> Compares the contents of this variable with the used
specified one and return a Boolean (True/False) representing the
result of the comparison. It can be set to =, !=, <,>, <= or>=.
<
value
> Specifies the value to be compared.
Example: SYS.eJ1939.TIRE_CPC_STAT_LEARN>=0
SYS.eJ1939.TIRE_CPC_TTM_STATE<
comp
><
value
>
This event is generated whenever the contents of the
SYS.eJ1939.TIRE_CPC_TTM_STATE variable changes.
<
comp
> Compares the contents of this variable with the used
specified one and return a Boolean (True/False) representing the
result of the comparison. It can be set to =, !=, <,>, <= or>=.
<
value
> Specifies the value to be compared.
Example: SYS.eJ1939.TIRE_CPC_TTM_STATE>=0
SYS.eJ1939.TIRE_CPC_TTM_ALARM<
comp
><
value
>
This event is generated whenever the contents of the
SYS.eJ1939.TIRE_CPC_TTM_ALARM variable changes.
<
comp
> Compares the contents of this variable with the used
specified one and return a Boolean (True/False) representing the
result of the comparison. It can be set to =, !=, <,>, <= or>=.
<
value
> Specifies the value to be compared.
Example: SYS.eJ1939.TIRE_CPC_TTM_ALARM>=0
SYS.eJ1939.TIRE_CPC_TTM_BAT<
comp
><
value
>
This event is generated whenever the contents of the
SYS.eJ1939.TIRE_CPC_TTM_BAT variable changes.
<
comp
> Compares the contents of this variable with the used
specified one and return a Boolean (True/False) representing the
result of the comparison. It can be set to =, !=, <,>, <= or>=.
<
value
> Specifies the value to be compared.
Example: SYS.eJ1939.TIRE_CPC_TTM_BAT>=0
SYS.eJ1939.TIRE_CPC_TTM_DEFECT<
comp
><
value
>
This event is generated whenever the contents of the
SYS.eJ1939.TIRE_CPC_TTM_DEFECT variable changes.
<
comp
> Compares the contents of this variable with the used
specified one and return a Boolean (True/False) representing the
result of the comparison. It can be set to =, !=, <,>, <= or>=.
<
value
> Specifies the value to be compared.
Example: SYS.eJ1939.TIRE_CPC_TTM_DEFECT>=0
SYS.eJ1939.TIRE_CPC_TTM_LOSE<
comp
><
value
>
This event is generated whenever the contents of the
SYS.eJ1939.TIRE_CPC_TTM_LOSE variable changes.
<
comp
> Compares the contents of this variable with the used
specified one and return a Boolean (True/False) representing the
result of the comparison. It can be set to =, !=, <,>, <= or>=.
<
value
> Specifies the value to be compared.
Example: SYS.eJ1939.TIRE_CPC_TTM_LOSE>=0
TTM=
Truck tire module “Sensor inside the tire”
Table 3
: Supported events for alarm configuration for
for ContiPressureCheck™
system