Configuration
4-6
4.7.6
Connect Mode
This parameter defines how the UTS makes a connection and how it reacts to
incoming connections over the network
Function
7
6
5
4
3
2
1
0
Connection acceptance
never accept incoming
0
0
0
Accept incoming with active DTR
only
0
1
0
Accept unconditional (if not busy)
1
1
0
Response on serial to connect
Nothing (quiet)
0
Character response: (C=conn.,
D=disc., N=not
available/unreachable)
1
Active connection startup
no active connection startup
0
0
0
0
start connection with any
character on serial line
0
0
0
1
start connection with active-going
DTR line
0
0
1
0
start connection with CR (0x0d)
only
0
0
1
1
Manual connection startup (‘C’ +
address)
0
1
0
0
Datagram Mode (separate doc)
1
1
0
0
Figure 4-3
Please refer to Appendix C on converting values to hexadecimal format.
4.7.7
Automatic Connection Address
For each serial port, an automatic TCP connection can be programmed—these
are the remote IP address and the TCP port number.
If automatic connection is selected, all parameters must be supplied.
If manual connection startup is configured (with “C” + address/port), only the
part not supplied in the command string is used. In manual mode, the last byte
of the address must be supplied.