6
Jumbo frame
10KB on all ports
Connectors
10/100TX: 16 x ports M12 4-pole D-coded with Auto MDI/MDI-X
function
10/100/1000T: 4 x ports M12 8-pole A-coded with Auto MDI/MDI-
X function (for
–X model
, is 4 x ports M12 8-pole
X-coded
with
Auto MDI/MDI-X function)
RS-232 connector: 1 x M12 5-pole A-coded
Power Input connector : 1 x M12 5-pole A-coded
Relay contact : 1 x M12 5-pole A-coded
Network Cable
10Base-T: 2-pair UTP/STP Cat. 3, 4, 5/ 5E/ 6 cable
EIA/TIA-568 100-ohm (100m)
100Base-TX: 2-pair UTP/STP Cat. 5/ 5E/ 6 cable
EIA/TIA-568 100-ohm (100m)
1000Base-TX: 2-pair UTP/STP Cat. 5/ 5E/ 6 cable
EIA/TIA-568 100-ohm (100m)
Bypass
Protection**
High-speed optical switching (<4ms)
Minimal insertion loss (Max 1.6dB as Bypass Mode)
Protocol
CSMA/CD
LED
Per unit: Power 1 (Green), Power 2 (Green), P-Fail (Red)
Ethernet port: Link/Activity (Green), Speed (Green)
DI/DO
1 Digital Input (DI) :
Level 0: -30~2V / Level 1: 10~30V
Max. input current:8mA
1 Digital Output(DO): Open collector to 40 VDC, 200mA
Operating
Humidity
5% ~ 95% (Non-condensing)
Operating
Temperature
-40°C~75°C / -40°F~167°F
(72V model: -40°C~60°C / -40°F~140°F)
Storage
Temperature
-40°C~85°C / -40°F~185°F
Power Supply
Standard model:9.5~60VDC dual input
72V model: 50.4~90VDC dual input
110V model : 43~137.5VDC dual input