42
5.14 Port
– Port Alert
Having ticked the
Syslog
/
SMTP
checkboxes, the event log/email alert will be sent to the
system log server and the SMTP server respectively. Also, Port event log/alert (link up,
link down, and both) can be sent to the system log server/SMTP server respectively by
setting the trigger condition.
System event selection:
There are 3 event types
—Device Cold Start,
Authentication Failure, and X-ring Topology Change. The checkboxes are not
available for ticking unless the
Syslog Client Mode
on the Syslog Configuration tab
and the
E-mail Alert
on the SMTP Configuration tab are enabled first.
Device cold start:
When the device executes cold start action, the system will
issue the event log/email alert to the system log/SMTP server respectively.
Authentication Failure:
When the SNMP authentication fails, the system will
issue the event log/email alert to the system log/SMTP server respectively.
MAC Violation:
When the MAC address has violated, the system will issue the
event log/email alert to the system log/SMTP server respectively.
Port event selection:
Also, before the drop-down menu items are available, the
Syslog Client Mode
selection item on the Syslog Configuration tab and the
Alert
selection item on the SMTP Configuration tab must be enabled first. Those
drop-down menu items have 3 selections
—
Link UP
,
Link Down
, and
Link UP &
Link Down
. Disable means no event will be sent to the system log/SMTP server.
Link UP:
The system will only issue a log message when the link-up event of
the port occurs.
Link Down:
The system will only issue a log message when the link-down
event of port occurs.
Link UP & Link Down:
The system will issue a log message at the time when
port connection is link-up and link-down.
Содержание IES-2204F
Страница 1: ...Lantech IPES 2204F IES 2204F User Manual V2 2 Aug 2017...
Страница 9: ...3 ifAlias Each port allows importing 128bits of alphabetic string of word on SNMP interface...
Страница 22: ...16 LC connector to the transceiver...
Страница 36: ...30 IP Addressing interface...
Страница 39: ...33 SNMP Agent Configuration interface...
Страница 44: ...38 Event Configuration interface...
Страница 46: ...40 5 12 Port Status It will show you the status of port configuration setting...
Страница 56: ...50 6 22 1 LLDP Neighbors It will show you the information about Port Neighbor via LLDP protocol...
Страница 72: ...66 Straight through cables schematic Cross over cables schematic...
Страница 75: ...69...