background image

                            3                       

 

UM-EN_LAN-WMBUS-SMK2  REV1.2

 

SMOKE DETECTOR MODES   

STANDBY MODE 

Green LED flashing once every 48 seconds means the smoke detector is 
in standby (operating) mode.

 

 

ALARM MODE 

Red LED flashing 3 times and horn emit 3 tones every 4 seconds. 
 

SILENCE FEATURE 

 

The  silence  features  can  temporarily  mute  an  alarm  for  up  to  8  minutes.     
To use this feature, press test/silence button on the smoke detector when 
it alarms. If the smoke concentration  around the smoke detector is still at 
an  alarming  level  after  8 minutes of  silence,  then  the smoke  detector  will 
re-alarm immediately.   
 

MALFUNCTION (ERROR) SIGNAL 

Please remove and replace the smoke detector if: 

 
 

Horn emits sound 1 time and yellow LED flashing once 48 seconds:

   

Detector does not work properly. 
 

Horn emits sound 3 times and yellow LED flashing 1 time: 

Smoke trouble. 
 

Horn emits sound 2 times and yellow LED flashing 1 time:

   

“Low sensitivity”. 

Horn emits sound 2 times and yellow LED flashing 2 times: 

“High sensitivity”. 
 

Horn emits sound 1 time and yellow LED flashing 1 time: 

The detector has low battery voltage. 

 

HUSH FEATURE 

 

 

The  hush  feature  can  temporarily  mute  warning  of  malfunctions  for  up  to 
one  hour.  To  use  this  feature,  press  the  test/silence  button  when  the 
smoke  detector  is  in  warning  (malfunction)  mode.  To  return  the  smoke 
detector to audible warning mode, press the test/silence button again. 
 

LOW BATTERY WARNING SIGNAL 

 

If  the  smoke  detector  horn  begins  to  beep  once  every  48  seconds  with 
yellow LED flashing, then the battery of the smoke detector is weak. This 
low battery warning signal should last for up to 7 days. The SMK2 battery 
for  smoke  detection  is  not  replaceable  so  the  detector  must  be  replaced 
with a new unit. 

 
END OF LIFE SIGNAL 

After 10 years of operation, an audible indication will be given that the 
smoke detector should be replaced. This indication is distinguished by   

horn emit sound 1 time and yellow LED flashing 4 times every 48 
seconds. 

 

MANUAL TEST OF THE SMOKE DETECTOR 

Test  the  smoke  detector  both  at  installation  and  then  regularly  (at  least 
monthly) by pressing firmly on the test button with your finger for around 1 
second until the horn sounds and then release your finger. The alarm horn 
will  emit  sound  at  least  3  times  with  the  red  LED  flashing.  If  the  smoke 
detector emits sound with yellow LED flashing every 48 seconds after the 
test is done, then the smoke detector is not working properly. See section 

MALFUNCTION (ERROR) SIGNAL

”. 

      This  type  of  test  is  the 

only  way  to  make  sure  that  the  smoke 

detector  unit  is  working  properly.  If  the  unit  fails  this  test,  then  it 
must be replaced immediately

 
If  you  have  been  away  from  home  more  than  1  week,  always  test  the 
detector manually when you return to home. 

 

 
NOTE:
 

If no manual test has been performed for 28 days, the device will 

do an automatic self-test to determine if everything is okay. The alarm horn 
will emit sound during this test.

 

 

WARNING:

 

Never  use  an  open  flame  of  any  kind  to  test  your  smoke 

detector since you  may cause fire  damage  to the  smoke  detector or  your 
home. The built-in test button accurately tests all functions and is the only 
correct way to test the unit.

 

 

 

WARNING

:

 When you are not testing the unit, but the alarm horn sounds, 

then the smoke detector has sensed smoke or combustion particles in the 
air. Investigate the cause of the alarm and take proper actions if the alarm 
is  correct.  The  alarm  could  be  caused  by  a  nuisance  situation,  such  as 
cooking smoke or a dusty furnace. If this happens, open a window, or fan 
the air to remove the smoke or dust. The alarm will turn off as soon as the 
air is completely clear. 

 
WARNING:
 

Do  not  dismantle,  disconnect  the  power,  or  remove  the 

battery  from  the  smoke  detector.  This  will  remove  your  protection  from 
fires

 
 
 

NOTE: 

If  the  smoke  detector  horn  begins  to  emit  sound  once  in  48 

seconds  with  yellow  LED  flashing,  then  the  smoke  detector

’s  battery  is 

weak.

 

 

NOTE:

 Only use the replacement lithium batteries listed below:   

1. (Duracell) DL123A                     
2. (Panasonic) CR123A 

WARNING:

 

  Do not use any other type of battery. The RF module of this 

smoke detector may not operate properly with another type of battery.

 

BATTERY INSTALLATION 

1. Open battery compartment (see figure below). 
2. Install 3V batte

ry into compartment and make sure the “+” and “-“ ends 

of the battery are aligned properly and close the hatch. 
3. After the battery is installed, mount it on the bracket and press the test 
button immediately to check if it alarms properly.  
 

CAUTION: 

Danger of explosion if battery is incorrectly replaced. 

Replace only with the same or equivalent type. 

 
CAUTION:

  This  smoke  detector  comes  with  a  cover  latch  that  will 

prevent the smoke detector cover from closing if the battery is not installed. 
This  tells  you  that  the  smoke  detector  will  not  work  until  a  battery  is 
properly installed.   

TAKING CARE OF YOUR SMOKE DETECTOR 

Your  SMK2  smoke  detector  is  designed  to  be  as  maintenance-free  as 
possible.  To  keep  your  smoke  detector  in  good  working  condition,  you 
must test the unit according to 

section “

MANUAL TEST OF THE SMOKE 

DETECTOR

”.

 

 

Regular Maintenance: 

Open  the  cover  and  vacuum  the  dust  off  the  smoke  detector

’s  sensing 

chamber at least once a month. 
 
To clean the smoke detector, use soft brush attachment  on your vacuum. 
Carefully  remove  any  dust  on  smoke  detector  components,  especially  on 
the  openings  of  the  sensing  chamber.  Test  the  smoke  detector  to  make 
sure  battery  is  working  correctly.  Never  use  water  cleaners  as  they  may 
damage the unit. 
 

 

 

NOTE: 

If nuisance alarms keep coming from the unit, you should check 

if  the  smoke  detector

’s location is adequate. Refer to section “

WHERE 

TO INSTALL SMOKE DETECTOR

” and move your smoke detector if it 

is not located properly. Clean the unit as described above. 
 