background image

HD62 User Manual

KS064300G4-Ver1.1

- 4 -

1. Monitor

2. Focus knob

3. Buttons

4. Switch

5. Monocular microscope

6. Magnification

adjustment ring

7. Base

8. TF card slot

9. HDMI port

10. Reset

11. USBport

12. Monitor switch

13. USB power supply

interface

14. HDMI interface

15. Wired controller

interface

12.5"monitor

For image display and USB power supply 

interface. 

Rotate the knob to implement the focus function; Rotate 

clockwise: back focal length decreases and object 

distance increases;  Rotate anticlockwise: back focal 

length increases and object distance decreases. 

In HDMI mode, 5 buttons can match to each other to 

achieve different functions. 

Put the switch to right: turn on the digital camera; put the 

switch to left: turn off the digital camera. 

Electronic eyepiece adopts standard C port. You can adjust 

the magnification ratio of the microscope according to 

requirements to realize object observation under different 

magnification ratio 

Adjustment range 0.7-5 times. 

Aluminum alloy base with scratch-resistant film on the 

surface. 

The location of TF card, photos and videos will be stored in 

TF card. 

Connect to the monitor with HDMI cable for signal 

transmission. 

Press and hold for more than 3 seconds to restore factory 

settings. 

Used for the connection between the camera and the 

monitor, which supplies power to the camera

.

When the switch is turned up, the monitor is turned on;

 

when the switch is turned down, the monitor is turned off 

(the digital camera stops working after the monitor is 

turned off). 

It is a 5V 2A power output interface, 

provide-power

 to 

digital camera through USB cable. 

Connect to the digital camera through HDMI 
cable to receive the signal from digital camera. 

Connect to the wired controller which is an optional 

accessory to adjust parameters of the monitor. 

Содержание HD62

Страница 1: ...LANOPTIK TECHNOLOGIES LTD HDMI Digital Microscope HD62 User Manual...

Страница 2: ...PTER 4 INSTALLATION GUIDE 6 4 1 Methods of application of electron microscope 6 CHAPTER 5 DIGITAL CAMERA INSTRUCTIONS 8 5 1 Instruction of manual focusing knob on the top of the digital camera 8 5 2 I...

Страница 3: ...the product under the following environment high temperature or high humidity environment places with direct sunlight dirt or vibration and places near heat source 7 Please use and store in the follo...

Страница 4: ...Packing List 1 Imaging part and arm 2 Monitor 3 Base 4 Upright column 5 Hand shank 6 AC DC adapter 7 HDMI cable 8 USB cable 9 inner hexagon spanner 10 Installation disk 11 Installation Guide 12 Reset...

Страница 5: ...HD62 User Manual KS064300G4 Ver1 1 3 Chapter 3 Function Introduction of Each Part 3 1 Name and Function for Each Part of Microscope...

Страница 6: ...adjust the magnification ratio of the microscope according to requirements to realize object observation under different magnification ratio Adjustment range 0 7 5 times Aluminum alloy base with scra...

Страница 7: ...t can be rotated 180 horizontally after loosening the knob After tightening the knob the pan tilt can be fixed at the current position Clockwise twist turn on the diffuse reflectance light strengthen...

Страница 8: ...wered by connecting to the adapter HDMI cable Power adapter Wired controller optional accessories Connecting the digital microscope to and monitor to achieve signal transmission between digital micros...

Страница 9: ...s image 3 4 lock the two inner hexagon screws with small L shaped hex wrench shown as image 4 5 Screw 2 handles into the articulated arm shown as image 5 0 Image 1 Image 2 Image 3 Image 4 2 Connection...

Страница 10: ...gle key to status of power on 3 Rotate the manual focusing knob clockwise or anti clockwise to adjust the eye height until the image is clearly displayed 1 Clockwise BFL gets shorter object distance i...

Страница 11: ...on Lock the current position of the lens 5 3 Articulating arm adjustment 1 Articulating arm strength adjustment 1 When the bracket cannot support the weight of the lens adjust the hex screw in the dir...

Страница 12: ...Mode Please ensure insert the TF card before operation press button for picture capture Pictures will be automatically saved into the Photo folder under TF card of Microscope folder 5 2 Introduction...

Страница 13: ...ction 6 Exposure Setup to enter the exposure setup interface The icon displayed on the Long press screen is When the icon flashes the moving cursor is at current for Top down cycle selection Press to...

Страница 14: ...up or close the real time white balance Red icon AWB stands for starting real time white balance and black AWB for closing real time white balance 2 With the cursor pointed to through button or to pro...

Страница 15: ...e a disk icon will be created on the computer and the file in TF card of the digital camera can be read through computer Note The maximum support of digital camera is 64G and do not support hot plug t...

Отзывы: