3.

 

Slide the adjustable brackets into the fixed brackets attached to the sides of the 
system. 

 

 

 

 

 

 

 
4.

 

Secure the adjustable brackets to the rack, using two (2) rack-mounting screws 
on each side. 

 
 
 
 
 
 
 
 
 
5.

 

Installation is complete.   

 

 
 
 

 

 

Mounting Installation Precautions:

 

The following should be considered for rack-mount or similar mounting installations:

 

 

The installation of this product must be performed by trained specialists; otherwise, a 
non-

specialist might create the risk of the system’s falling to the ground or other 

damages.   

 

For fixed mounting only. To prevent hazards, do not slide unit out on brackets or hang 
unsecured system from brackets.   

 

Do not stack additional weight on top of rack mount system.     

 

Lanner Electronics Inc. shall not be held liable for any losses resulting from insufficient 
strength for supporting the system or use of inappropriate installation components. 

 

Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the 
operating ambient temperature of the rack environment may be greater than room 
ambient. Therefore, consideration should be given to installing the equipment in an 
environment compatible with the maximum ambient temperature (Tma) specified by the 
manufacturer.   

 

Reduced Air Flow - Installation of the equipment in a rack should be such that the 
amount of airflow required for safe operation of the equipment is not compromised.   

 

Mechanical Loading - Mounting of the equipment in the rack should be such that a 
hazardous condition is not achieved due to uneven mechanical loading.   

 

Circuit Overloading - Consideration should be given to the connection of the equipment 
to the supply circuit and the effect that overloading of the circuits might have on 
overcurrent protection and supply wiring. Appropriate consideration of equipment 
nameplate ratings should be used when addressing this concern. 

 

Reliable Grounding - Reliable grounding of rack mounted equipment should be 
maintained. Particular attention should be given to supply connections other than direct 
connections to the branch circuit (e.g. use of power strips).

 

 

 

 