Lanner FW-8877 Скачать руководство пользователя страница 43

37

Driver  Installation

Appendix D

Network Application Platforms

On Linux

Follow  these  instructions  when  installing  the  Intel® 

LAN controller base driver for the in Red Hat® and Linux 

operating system.

  Insert  the  motherboard/system  support  CD  to  the 

1. 

optical drive and mount the optional drive in the Linux 

platform.   
Copy  the  base  driver  tar  file  from  the  motherboard/

2. 

system support CD to the directory of your local hard 

disk.  The Intel® LAN driver for Linux OS is located in the 

following directory:

\Driver\LAN_Driver\PRO1000\LINUX. The name format 

of  driver  file  is “e1000-<Version>.tar.gz”.  For  example: 

the file name of driver version 7.0.38 is “e1000-7.0.38. 

tar.gz”.

Untar/unzip the archive, where <x.x.x> is the version 

3. 

number for the driver tar file:

          tar zxf e1000-<x.x.x>.tar.gz 

Change  to  the  driver  src  directory  on  your  system, 

4. 

where <x.x.x> is the version number for the driver tar:

          cd e1000-<x.x.x>/src/ 

Compile  the  driver  module  by  typing  the  following 

5. 

command:

          make install 

The binary will be installed as:

6. 

        /lib/modules/<kernel_version>/kernel/drivers/net/

e1000.o
           The  install  locations  listed  above  are  the  default 

locations. They might not be correct for certain Linux 

distributions.

Load the module using either the insmod or modprobe 

7. 

command:

     

modprobe igb

     

insmod igb

 

Note  that  for  2.6  kernels  the  insmod  command 

can be used if the full path to the driver module is specified. 

For example:
        insmod  /lib/modules/<KERNEL  VERSION>/kernel/

drivers/net/igb/igb.ko
 

With 2.6 based kernels also make sure that older 

igb drivers are removed from the kernel, before loading 

the new module:
 

    rmmod igb; modprobe igb

Assign an IP address to the interface by entering the 

8. 

following, where <x> is the interface number:

          ifconfig eth<x> <IP_address> 

  Verify  that  the  interface  works.  Enter  the  following, 

9. 

where  <IP_address>  is  the  IP  address  for  another 

machine on the same subnet as the interface that is 

being tested:

          ping <IP_address>

Note:  The system uses Intel I210 Ethernet 

controllers, you could obtain the latest drivers at 

the Intel download center:

http://downloadcenter.intel.com/

Содержание FW-8877

Страница 1: ...Network Application Platforms Hardware platforms for next generation networking infrastructure FW 8877 V1 2 User s Manual Publication date 2015 02 23...

Страница 2: ...er the original manufacturer assumes no responsibility for its use nor for any infringements upon the rights of third parties that may result from such use Acknowledgement Intel Pentium and Celeron ar...

Страница 3: ...ulation Be sure that the room in which you choose to operate your system has adequate air circulation Ensure that the chassis cover is secure The chassis design allows cooling air to circulate effecti...

Страница 4: ...e ad quate pour refroidir l quipement une temp rature de fonctionnement acceptable sans circulation adapt e V rifiez que votre site propose une circulation d air ad quate V rifiez que le couvercle du...

Страница 5: ...plication Platforms Revision History Version Changes 1 1 Add the IPMI board connector LOM1 de scription in the introduction part page 3 Add FastBoot option description in the BIOS 1 2 Modified rear PC...

Страница 6: ...oard Layout 11 Jumper Settings 12 Chapter 4 BIOS Settings 16 Accessing the BIOS menu 16 Navigating the BIOS menu 16 The Main Menu 17 Advanced Settings 18 Chipset 27 Boot Configuration 28 Security Sett...

Страница 7: ...600 series Chipset OS Support Windows 7 8 2000 Vista Server 2008 2012 Linux Kernel 2 6 or above BIOS AMI BIOS 64Mb System Memory Technology Quad channel DDR3 800 1066 1333 1600 MHz Registered ECC Ecc...

Страница 8: ...ents Your package contains the following items FW 8877 Network Security Platform 1 passive CPU heatsink 2 power cables 1 crossover Ethernet cable 1 8 meters 1 straight through Ethernet cable 1 8 meter...

Страница 9: ...onnected for configuration or troubleshooting purpose Conformity with IPMI Intelligent PlatformManagementInterface canbeimplementedthroughOPMAonthisinterface Youneedtoswitchtheconnectors on the mainbo...

Страница 10: ...f the Intel Virtualization Technology to improve networking and I O throughput on a virtualized system Turn on the Virtualization support on the chipset refer to Chapter 4 BIOS Settings for more infor...

Страница 11: ...Switch When the alarm sounds it indicates a power supply failure switch off this button to turn off the alarm Replace the failed power supply as soon as possible R5 Redundant Power Supply The 400W re...

Страница 12: ...the higher bandwidth requirements of the latest operating system and Internet applications It comes with Quad Channel DDR3 Dual Inline Memory Modules DIMM sockets Open the DIMM slot latches 1 Install...

Страница 13: ...the sequence as instructed on the right to release both of them Lift the load lever and then the plate 3 Align the cut edge of the CPU and the notch on the 4 socket The CPU should fit perfectly into...

Страница 14: ...he hard disk with the mounting holes on the tray Secure the hard disk with 4 mounting screws on the 3 hard disk tray Connect the Serial ATA power and data cables to the 4 hard disk s power and data co...

Страница 15: ...9 Hardware Setup Chapter 2 Network Application Platforms...

Страница 16: ...6 1333 1600MHz ECC Non ECC DIMM Compact Flash SPIF 223A Com Ports LCM Key Pad GPIO Fan Monitor SPI 64Mb Flash 2x USB for front IO W83627DHG Thermal Monitor DMI Intel Patsburg J PCH LPC SATAII USB 2 0...

Страница 17: ...picture as a reference of the pin assignments and the internal connectors OPMA1 USB2 DIMM Socket AJ1 AJ2 BJ1 BJ2 Reset Switch SW2 LOM1 Fan 2 DIMM Socket DJ2 DJ1 CJ2 CJ1 CPU Socket No 1 AT Mode Power...

Страница 18: ...ATA4 SATA Revision II Drive Connector It is for connecting a 3 5 SATA harddisk to be served as your system s storage The system can support up to one 3 5 or two 2 5 disks in maximum The system s BIOS...

Страница 19: ...ux kernel version 2 6 27 the mdadm utility 3 0 supports RAID 0 RAID 1 RAID 5 and RAID 10 To use the RAID features in dmraid and mdadm you will need to set up the RAID volume using the Intel Matrix Sto...

Страница 20: ...face connector CF1 CF Card Connector Pin No Description Pin No Description 1 GND 26 CD1 2 DATA3 27 DATA11 3 DATA4 28 DATA12 4 DATA5 29 DATA13 5 DATA6 30 DATA14 6 DATA7 31 DATA15 7 CE1 32 CE2 8 A10 33...

Страница 21: ...per to reset the BIOS setting to its factory default TTL1 Redundant power Supply TTL time to live signal It detects and reads the operating status of the power supply 3 2 1 and white latched slots is...

Страница 22: ...or by pressing the reset button on the system chassis You can also restart by turning the system off and then back on Do this last option only if the first two failed The Setup program is designed to...

Страница 23: ...blue can be modified The right frame displays the key legend Above the key legend is an area reserved for a text message When an option is selected in the left frame it is highlighted in white Often...

Страница 24: ...scribed on the following pages Restore AC Power Loss This option lets you set the state of the system when it has just recovered from a power outage Option Description Power Off When setting to Power...

Страница 25: ...em Use the Plus and Minus keys to change the value of the selected option A description of the selected item appears on the right side of the screen The settings are described below Item Selection Int...

Страница 26: ...etch of next L1 line based on sequential load history Intel Virtual ization The Intel VT is a hardware assisted virtual ization This processor supports Intel Vir tualization Enable or disable this fea...

Страница 27: ...nly available on SATA controllers that use the Advanced Host Controller Interface AHCI Serial ATA Port 0 1 2 3 4Use this menu to configure specific SATA Port for all ports on the system Option Descrip...

Страница 28: ...SB compatible operating system is fully booted with all USB drivers loaded When this option is enabled any attached USB mouse or USB keyboard can be used on the system even when there is no USB driver...

Страница 29: ...re Delays a The menu sets delay time for USB operations Item Description USB transfer time out set transfers to an endpoint to complete within a specific time If set to zero transfers will not time ou...

Страница 30: ...or automatically detects the voltage output through the onboard voltage regulators Smart Fan Mode Configuration It allows you to configure the smart fan feature You can manually turn on the fans or en...

Страница 31: ...ip Serial Port 0 1 Configuration This option specifies the base I O port address and Interrupt Request address of serial port 0 and 1 item Selection Enabled Disabled Set this value to prevent the seri...

Страница 32: ...Redirection Enable or disable BIOS through remote access Console Redirection Set tings Enter to view more options COM0 COM1 Console Redirection Settings Item Selection Terminal Type Sets the connecti...

Страница 33: ...ngs Chapter 4 Network Application Platforms Chipset The chipset menu will let you further configure your Intel PCH information It also shows the memory capacity of the system and the installed memory...

Страница 34: ...figure the boot procedures and the related elements Items Options Setup Prompt Timeout Specify the number of seconds for the boot setup prompt to wait for user s intervention during the POST Bootup Nu...

Страница 35: ...se you will only be able to see or change selected fields in the BIOS setup program User Password If you have set a user password you must enter the user password for booting the system and accessing...

Страница 36: ...ers can take effect Discard Changes and Reset This option allows you to discard the selections you made and restore the previously saved values After selecting this option a confirmation appears Selec...

Страница 37: ...e counter reach zero before the software restarts it the software is presumed to be malfunctioning and the processor s reset signal is asserted Thus the processor will be restarted as if a human opera...

Страница 38: ...cable to console port 1 of the system and the other end to serial port of the Remote Client System Configure the following settings in the BIOS Setup 2 menu BIOS Advanced Remote Access Configuration...

Страница 39: ...Note omit the file extensions After compiled the executable programs plcm_test plcm_cursor_char Test and the driver plcm_drv ko or plcm_drv o will appear in the program s folder Note The OS supported...

Страница 40: ...allation on platforms 2 other than Linux see lanner serial usb lcm v0 5 README and lanner serial usb lcm v0 5 dos example README Install To install type the following command mknod dev usb hiddev0 c 1...

Страница 41: ...pset driveronaWindowsOperating System Restart the computer and then log on with 1 Administrator privileges Insert the Drivers and User s Manual CD to the USB 2 optical drive Browse the contents of the...

Страница 42: ...izard window appears Select the I accept the terms in the license agreement 6 and then click Next Select the programs that you wish to install Make sure 7 that you have selected the drivers Click Nest...

Страница 43: ...er module by typing the following 5 command make install The binary will be installed as 6 lib modules kernel_version kernel drivers net e1000 o The install locations listed above are the default loca...

Страница 44: ...er s Manual CD to the optical 1 drive Or you can download this software from Intel website too Browse the contents of the support CD under the 2 directory Driver for RAID software Follow the on screen...

Страница 45: ...ll be returned at customer s expense The following conditions are excluded from this 5 warranty Improper or inadequate maintenance by the customer Unauthorized modification misuse or reversed engineer...

Страница 46: ...ing by Air Freight Sea Express ___ Others ________________ Item Model Name Serial Number Configuration Item Problem Code Failure Status Problem Code 01 D O A 02 Second Time R M A 03 CMOS Data Lost 04...

Отзывы: