Lanner FW-8877 Скачать руководство пользователя страница 3

ii

About

About

Network Application Platforms

EMC Notice

This  equipment  has  been  tested  and  found  to  comply 

with the limits for a Class A digital device, pursuant to Part 

15 of the FCC Rules. These limits are designed to provide 

reasonable protection against harmful interference when 

the equipment is operated in a commercial environment. 

This  equipment  generates,  uses,  and  can  radiate  radio 

frequency  energy  and,  if  not  installed  and  used  in 

accordance  with  the  instruction  manual,  may  cause 

harmful interference to radio communications. Operation 

of  this  equipment  in  a  residential  area  is  likely  to  cause 

harmful interference in which case users will be required 

to correct the interference at their own expense. 

Safety Guidelines

Follow these guidelines to ensure general safety:

Keep the chassis area clear and dust-free during and 

• 

after installation.
Do not wear loose clothing or jewelry that could get 

• 

caught in the chassis. Fasten your tie or scarf and roll 

up your sleeves. 
Wear  safety  glasses  if  you  are  working  under  any 

• 

conditions that might be hazardous to your eyes. 
Do  not  perform  any  action  that  creates  a  potential 

• 

hazard to people or makes the equipment unsafe.
Disconnect  all  power  by  turning  off  the  power  and 

• 

unplugging  the  power  cord  before  installing  or 

removing a chassis or working near power supplies
Do not work alone if potentially hazardous conditions 

• 

exist. 
Never  assume  that  power  is  disconnected  from  a 

• 

circuit; always check the circuit. 

LITHIUM BATTERY CAUTION: 

  

Risk of Explosion if Battery is replaced by an incorrect type. 

Dispose of used batteries according to the instructions.

Installation  only  by  a  trained  electrician  or  only  by 

• 

an electrically trained person who knows all English 

Installation and Device Specifications which are to be 

applied.
Do  not  carry  the  handle  of  power  supplies  when 

• 

moving to other place.
The machine can only be used in a fixed location such 

• 

as labs or computer facilities.

Operating Safety

Electrical equipment generates heat. Ambient air 

• 

temperature may not be adequate to cool equipment to 

acceptable operating temperatures without adequate 

circulation. Be sure that the room in which you choose to 

operate your system has adequate air circulation. 
Ensure that the chassis cover is secure. The chassis design 

• 

allows cooling air to circulate effectively. An open chassis 

permits air leaks, which may interrupt and redirect the flow 

of cooling air from internal components.

Electrostatic discharge (ESD) can damage equipment and 

impair electrical circuitry. ESD damage occurs when electronic 

components are improperly handled and can result in complete 

or intermittent failures. Be sure to follow ESD-prevention 

procedures when removing and replacing components to avoid 

these problems. 

Wear an ESD-preventive wrist strap, ensuring that it makes 

• 

good skin contact. If no wrist strap is available, ground 

yourself by touching the metal part of the chassis.
Periodically check the resistance value of the antistatic 

• 

strap, which should be between 1 and 10 megohms 
(Mohms).

 

Rack Mounting Installation Environment Precaution

Elevated Operating Ambient - If installed in a closed 

1. 

or multi-unit rack assembly, the operating ambient 

temperature of the rack environment may be greater than 

room ambient. Therefore, consideration should be given 

to installing the equipment in an environment compatible 

with the maximum ambient temperature (Tma) specified 

by the manufacturer.
Reduced Air Flow - Installation of the equipment in a rack 

2. 

should be such that the amount of air flow required for 

safe operation of the equipment is not compromised. 

Mechanical Loading - Mounting of the equipment in the 

rack should be such that a hazardous condition is not 

created due to uneven mechanical loading.
Mechanical Loading - Mounting of the equipment in the 

3. 

rack should be such that a hazardous condition is not 

achieved due to uneven mechanical loading.
Circuit Overloading - Consideration should be given to 

4. 

the connection of the equipment to the supply circuit and 

the effect that overloading of the circuits might have on 

over-current protection and supply wiring. Appropriate 

consideration of equipment nameplate ratings should be 

used when addressing this concern.
Reliable Earthing - Reliable earthing of rack-mounted 

5. 

equipment should be maintained. Particular attention 

should be given to supply connections other than direct 

connections to the branch circuit (e.g. use of power strips).”

Содержание FW-8877

Страница 1: ...Network Application Platforms Hardware platforms for next generation networking infrastructure FW 8877 V1 2 User s Manual Publication date 2015 02 23...

Страница 2: ...er the original manufacturer assumes no responsibility for its use nor for any infringements upon the rights of third parties that may result from such use Acknowledgement Intel Pentium and Celeron ar...

Страница 3: ...ulation Be sure that the room in which you choose to operate your system has adequate air circulation Ensure that the chassis cover is secure The chassis design allows cooling air to circulate effecti...

Страница 4: ...e ad quate pour refroidir l quipement une temp rature de fonctionnement acceptable sans circulation adapt e V rifiez que votre site propose une circulation d air ad quate V rifiez que le couvercle du...

Страница 5: ...plication Platforms Revision History Version Changes 1 1 Add the IPMI board connector LOM1 de scription in the introduction part page 3 Add FastBoot option description in the BIOS 1 2 Modified rear PC...

Страница 6: ...oard Layout 11 Jumper Settings 12 Chapter 4 BIOS Settings 16 Accessing the BIOS menu 16 Navigating the BIOS menu 16 The Main Menu 17 Advanced Settings 18 Chipset 27 Boot Configuration 28 Security Sett...

Страница 7: ...600 series Chipset OS Support Windows 7 8 2000 Vista Server 2008 2012 Linux Kernel 2 6 or above BIOS AMI BIOS 64Mb System Memory Technology Quad channel DDR3 800 1066 1333 1600 MHz Registered ECC Ecc...

Страница 8: ...ents Your package contains the following items FW 8877 Network Security Platform 1 passive CPU heatsink 2 power cables 1 crossover Ethernet cable 1 8 meters 1 straight through Ethernet cable 1 8 meter...

Страница 9: ...onnected for configuration or troubleshooting purpose Conformity with IPMI Intelligent PlatformManagementInterface canbeimplementedthroughOPMAonthisinterface Youneedtoswitchtheconnectors on the mainbo...

Страница 10: ...f the Intel Virtualization Technology to improve networking and I O throughput on a virtualized system Turn on the Virtualization support on the chipset refer to Chapter 4 BIOS Settings for more infor...

Страница 11: ...Switch When the alarm sounds it indicates a power supply failure switch off this button to turn off the alarm Replace the failed power supply as soon as possible R5 Redundant Power Supply The 400W re...

Страница 12: ...the higher bandwidth requirements of the latest operating system and Internet applications It comes with Quad Channel DDR3 Dual Inline Memory Modules DIMM sockets Open the DIMM slot latches 1 Install...

Страница 13: ...the sequence as instructed on the right to release both of them Lift the load lever and then the plate 3 Align the cut edge of the CPU and the notch on the 4 socket The CPU should fit perfectly into...

Страница 14: ...he hard disk with the mounting holes on the tray Secure the hard disk with 4 mounting screws on the 3 hard disk tray Connect the Serial ATA power and data cables to the 4 hard disk s power and data co...

Страница 15: ...9 Hardware Setup Chapter 2 Network Application Platforms...

Страница 16: ...6 1333 1600MHz ECC Non ECC DIMM Compact Flash SPIF 223A Com Ports LCM Key Pad GPIO Fan Monitor SPI 64Mb Flash 2x USB for front IO W83627DHG Thermal Monitor DMI Intel Patsburg J PCH LPC SATAII USB 2 0...

Страница 17: ...picture as a reference of the pin assignments and the internal connectors OPMA1 USB2 DIMM Socket AJ1 AJ2 BJ1 BJ2 Reset Switch SW2 LOM1 Fan 2 DIMM Socket DJ2 DJ1 CJ2 CJ1 CPU Socket No 1 AT Mode Power...

Страница 18: ...ATA4 SATA Revision II Drive Connector It is for connecting a 3 5 SATA harddisk to be served as your system s storage The system can support up to one 3 5 or two 2 5 disks in maximum The system s BIOS...

Страница 19: ...ux kernel version 2 6 27 the mdadm utility 3 0 supports RAID 0 RAID 1 RAID 5 and RAID 10 To use the RAID features in dmraid and mdadm you will need to set up the RAID volume using the Intel Matrix Sto...

Страница 20: ...face connector CF1 CF Card Connector Pin No Description Pin No Description 1 GND 26 CD1 2 DATA3 27 DATA11 3 DATA4 28 DATA12 4 DATA5 29 DATA13 5 DATA6 30 DATA14 6 DATA7 31 DATA15 7 CE1 32 CE2 8 A10 33...

Страница 21: ...per to reset the BIOS setting to its factory default TTL1 Redundant power Supply TTL time to live signal It detects and reads the operating status of the power supply 3 2 1 and white latched slots is...

Страница 22: ...or by pressing the reset button on the system chassis You can also restart by turning the system off and then back on Do this last option only if the first two failed The Setup program is designed to...

Страница 23: ...blue can be modified The right frame displays the key legend Above the key legend is an area reserved for a text message When an option is selected in the left frame it is highlighted in white Often...

Страница 24: ...scribed on the following pages Restore AC Power Loss This option lets you set the state of the system when it has just recovered from a power outage Option Description Power Off When setting to Power...

Страница 25: ...em Use the Plus and Minus keys to change the value of the selected option A description of the selected item appears on the right side of the screen The settings are described below Item Selection Int...

Страница 26: ...etch of next L1 line based on sequential load history Intel Virtual ization The Intel VT is a hardware assisted virtual ization This processor supports Intel Vir tualization Enable or disable this fea...

Страница 27: ...nly available on SATA controllers that use the Advanced Host Controller Interface AHCI Serial ATA Port 0 1 2 3 4Use this menu to configure specific SATA Port for all ports on the system Option Descrip...

Страница 28: ...SB compatible operating system is fully booted with all USB drivers loaded When this option is enabled any attached USB mouse or USB keyboard can be used on the system even when there is no USB driver...

Страница 29: ...re Delays a The menu sets delay time for USB operations Item Description USB transfer time out set transfers to an endpoint to complete within a specific time If set to zero transfers will not time ou...

Страница 30: ...or automatically detects the voltage output through the onboard voltage regulators Smart Fan Mode Configuration It allows you to configure the smart fan feature You can manually turn on the fans or en...

Страница 31: ...ip Serial Port 0 1 Configuration This option specifies the base I O port address and Interrupt Request address of serial port 0 and 1 item Selection Enabled Disabled Set this value to prevent the seri...

Страница 32: ...Redirection Enable or disable BIOS through remote access Console Redirection Set tings Enter to view more options COM0 COM1 Console Redirection Settings Item Selection Terminal Type Sets the connecti...

Страница 33: ...ngs Chapter 4 Network Application Platforms Chipset The chipset menu will let you further configure your Intel PCH information It also shows the memory capacity of the system and the installed memory...

Страница 34: ...figure the boot procedures and the related elements Items Options Setup Prompt Timeout Specify the number of seconds for the boot setup prompt to wait for user s intervention during the POST Bootup Nu...

Страница 35: ...se you will only be able to see or change selected fields in the BIOS setup program User Password If you have set a user password you must enter the user password for booting the system and accessing...

Страница 36: ...ers can take effect Discard Changes and Reset This option allows you to discard the selections you made and restore the previously saved values After selecting this option a confirmation appears Selec...

Страница 37: ...e counter reach zero before the software restarts it the software is presumed to be malfunctioning and the processor s reset signal is asserted Thus the processor will be restarted as if a human opera...

Страница 38: ...cable to console port 1 of the system and the other end to serial port of the Remote Client System Configure the following settings in the BIOS Setup 2 menu BIOS Advanced Remote Access Configuration...

Страница 39: ...Note omit the file extensions After compiled the executable programs plcm_test plcm_cursor_char Test and the driver plcm_drv ko or plcm_drv o will appear in the program s folder Note The OS supported...

Страница 40: ...allation on platforms 2 other than Linux see lanner serial usb lcm v0 5 README and lanner serial usb lcm v0 5 dos example README Install To install type the following command mknod dev usb hiddev0 c 1...

Страница 41: ...pset driveronaWindowsOperating System Restart the computer and then log on with 1 Administrator privileges Insert the Drivers and User s Manual CD to the USB 2 optical drive Browse the contents of the...

Страница 42: ...izard window appears Select the I accept the terms in the license agreement 6 and then click Next Select the programs that you wish to install Make sure 7 that you have selected the drivers Click Nest...

Страница 43: ...er module by typing the following 5 command make install The binary will be installed as 6 lib modules kernel_version kernel drivers net e1000 o The install locations listed above are the default loca...

Страница 44: ...er s Manual CD to the optical 1 drive Or you can download this software from Intel website too Browse the contents of the support CD under the 2 directory Driver for RAID software Follow the on screen...

Страница 45: ...ll be returned at customer s expense The following conditions are excluded from this 5 warranty Improper or inadequate maintenance by the customer Unauthorized modification misuse or reversed engineer...

Страница 46: ...ing by Air Freight Sea Express ___ Others ________________ Item Model Name Serial Number Configuration Item Problem Code Failure Status Problem Code 01 D O A 02 Second Time R M A 03 CMOS Data Lost 04...