UL File# E8138 Rev
8
Installation
DANGER
THIS APPLIANCE MUST BE GROUNDED AT THE TERMINAL PROVIDED.
FAILURE TO GROUND THE APPLIANCE COULD RESULT IN
ELECTROCUTION AND DEATH.
WARNING
INSTALLATION OF THE UNIT MUST BE DONE BY PERSONNEL
QUALIFIED TO WORK WITH ELECTRICITY AND PLUMBING. IMPROPER
INSTALLATION CAN CAUSE INJURY TO PERSONNEL AND/OR DAMAGE
TO EQUIPMENT. UNIT MUST BE INSTALLED IN ACCORDANCE WITH ALL
APPLICABLE CODES.
NOTICE
The data plate is located on the right hand side of the oven. Voltage,
wattage, serial number, wire size, and clearance specifications are on the
data plate. This information should be carefully read and understood
before proceeding with the installation.
NOTICE
The installation of any components such as a vent hood, grease
extractors and fire extinguisher systems must conform to their applicable
National, State and locally recognized installation standards.
Range Installation
The Range will come pre-assembled with the casters already installed.
Electrical Connection
The electrical connection must be made in accordance with local codes or,
in the absence of local codes, with NFPA No. 70, latest edition (in Canada
use CSA STD. C22.1).
The electrical service entrance is provided by a 1-1/4-inch knockout at the
range back directly behind the control compartment. A grounding lug is
provided at the rear service entrance.
The R30C (PT) may have been purchased with a cord & plug kit. This kit
includes a 48" cord with a NEMA L15-30P plug.
Range Voltage
The Lang Model R30C range operates as shipped on either 208V or 240V
(single or three phase) and 480V (three phase). Amperages, KW rating and
phasing can be found in the wiring diagram section of this manual.