5
INSTALLATION
RECEIVING THE GRIDDLE
Upon receipt, check for freight damage, both visible and concealed. Visible damage should be noted on the freight
bill at the time of delivery and signed by the carrier's agent. Concealed loss or damage means loss or damage, which
does not become apparent until the merchandise has been unpacked.
If concealed loss or damage is discovered upon unpacking, make a written request for inspection by the carrier's
agent within 15 days of delivery. All packing material should be kept for inspection.
Do not return damaged merchandise to Lang Manufacturing Company. File your claim with the carrier.
Prior to un-crating, move the range as near its intended location as practical. The crating will help protect the unit
from the physical damage normally associated with moving it through hallways and doorways.
ELECTRICAL CONNECTION
LG / LGS
There is one power supply connection on 2, 3 and 4 foot griddles. There are two power supply connections on 5 and
6-foot griddles. Refer to the power supply chart in the Technical Data portion of this manual, for proper power
supply size.
There is (1) one 1 1/4-inch conduit knockout on 2, 3, and 4-foot griddles located at the rear of the griddle, through
the back and the bottom of the griddle body. There are (2) two 1 1/4-inch conduit knockouts provided on the 5 and 6
foot griddles. Use a supply wire suitable for at least 90 degree centigrade.
The model LG-S griddle is shipped from the factory wired for 208/240 or 480 volts, the 208/240 griddle is a dual
voltage design. Jumper wires on terminal strip next to the main power supply connection determine the griddle
voltage. For a 208 volt power supply, leave the jumpers in place. For a 240 volt power supply disconnect the
jumpers as indicated on the tag to the terminal strip. The 480 volt griddle can be operated on 480 volts only.
PB
All PB-24 grills are supplied with a 48” 10 gauge cord and a NEMA L6-30P plug.
The PB-12 grill is supplied with a 48” 12 gauge cord and a NEMA L6-30P plug on the 240 Volt and NEMA 5-15P
plug on the 120 Volt
XL HOOD
Power connection can be made at a two pole terminal block located next to the power connection on the grill.
All XL Hoods are single phase and come in either 208 Volt or 240 Volt.
Содержание LG-24
Страница 16: ...15 WIRING DIAGRAM LG 208 240...
Страница 17: ...16 WIRING DIAGRAM LG 480...
Страница 18: ...17 WIRING DIAGRAM LG S 208 240...
Страница 19: ...18 WIRING DIAGRAM LGS 480...
Страница 20: ...19 PB 24 208 240 WIRING DIAGRAM...
Страница 21: ...20 PB 12 120 WIRING DIAGRAM...
Страница 22: ...21 PB 12 208 240 WIRING DIAGRAM...
Страница 23: ...22 XL HOOD...