UL File E8138
17
TROUBLESHOOTING CONT’D
NOTICE
Service on this, or any other, STAR appliance must be performed by qualified
personnel only. Consult your authorized service agent directory or call the
factory at 1-800-807-9054 or visit our website
WWW.STAR-MFG.COM
For the
service agent nearest you.
WARNING
BOTH HIGH AND LOW VOLTAGES ARE PRESENT INSIDE THIS APPLIANCE
WHEN THE UNIT IS PLUGGED/WIRED INTO A LIVE RECEPTACLE. BEFORE
REPLACING ANY PARTS, DISCONNECT THE UNIT FROM THE ELECTRIC POWER
SUPPLY.
CAUTION
USE OF ANY REPLACEMENT PARTS OTHER THAN THOSE SUPPLIED BY STAR
MANUFACTURING OR THEIR AUTHORIZED DISTRIBUTORS CAN CAUSE
BODILY INJURY TO THE OPERATOR AND DAMAGE TO THE EQUIPMENT AND
WILL VOID ALL WARRANTIES.
TESTS
Possible Cause
TEST
Blown fuses
No test available, replace fuses
Failed or tripped internal breaker
Reset breaker
Failed thermostat
Verify calibration Replace if necessary*
Failed Contactor
Verify that coil has correct voltage*
Verify that coil has continuity*
Verify that contactor points move
Failed 3-heat switch
Call factory or consult Service manual for
correct checks on each switch*
Failed element
Remove the wires and check for continuity
across the element*
Defective motor
Verify that motor wheel spins freely Verify
that motor has correct voltage*
Product is not baking properly
Verify thermostat calibration
*
A factory authorized service representative should perform this work.