14
Operation
IL1813
Control
Display:
2 X 20 character alfa-numeric display
Left/Right
Arrow:
Used to enter temperature set-point override mode and to cycle
from one section to the next. Also to cycle through adjustable
parameters in adjust mode.
Up/Down Arrow:
Used to adjust parameter values. (I.E.: Temperature, Time,
Yes/No).
Enter:
Used to enter adjustments into program memory, cycle to the
next adjustable parameter and/or return to normal operation.
Switch:
(HE models only) This switch turns on the power to the Clamshell®
Hood. When not using the hood, have this in the “OFF” position.
Starting the Griddle
Press the “Power” button.
The control will conduct a self test then display “
Control ready
” At this time the
ignition sequence will begin. Each burner will light and the control will heat to
the current temperature set point.
NOTICE
Once the griddle set point temperature has been changed, it will
heat to that setting each time the griddle is turned on. Refer to
"Changing the Griddle Temperature."
As the griddle heats, the display will scroll through the griddle sections
displaying the burner status, actual temperature, and temperature set point.