background image

 

2

 

THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE.  
READ, UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND 
WARNINGS CONTAINED IN THIS MANUAL. 

 

FOR YOUR SAFETY 

DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE 
VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY 
OTHER APPLIANCE. 

POST IN A PROMINENT LOCATION 

INSTRUCTIONS TO BE FOLLOWED IN THE EVENT USER 
SMELLS GAS.  THIS INFORMATION SHALL BE OBTAINED BY 
CONSULTING YOUR LOCAL GAS SUPPLIER.  AS A MINIMUM, 
TURN OFF THE GAS AND CALL YOUR GAS COMPANY AND 
YOUR AUTHORIZED SERVICE AGENT.  EVACUATE ALL 
PERSONNEL FROM THE AREA. 
 
WARNING:  IMPROPER INSTALLATION, ADJUSTMENT, 
ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE 
PROPERTY DAMAGE, INJURY OR DEATH.  READ THE 
INSTALLATION, OPERATING AND MAINTENANCE 
INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR 
SERVICING THIS EQUIPMENT. 

 
Model #: 

Purchased From: 
 

Serial #: 
 

Location: 

Date Purchased: 
 

Date Installed: 
 

Purchase Order #: 
 

For Service, Call: 
 

Содержание 160TT

Страница 1: ...ng 10 Sunnen Drive St Louis MO 63143 Part Number 2M W348 Phone 314 678 6315 Fax 314 781 2714 Rev B www langworld com MAY 31 2007 Installation Operation Maintenance Troubleshooting Drop In Teppanyaki Griddle Model 160TT ...

Страница 2: ...ELLS GAS THIS INFORMATION SHALL BE OBTAINED BY CONSULTING YOUR LOCAL GAS SUPPLIER AS A MINIMUM TURN OFF THE GAS AND CALL YOUR GAS COMPANY AND YOUR AUTHORIZED SERVICE AGENT EVACUATE ALL PERSONNEL FROM THE AREA WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ THE INSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BE...

Страница 3: ...GE 1 TABLE OF CONTENTS 3 2 READ FIRST 4 3 EQUIPMENT DESCRIPTION 6 4 UNPACKING 7 5 INSTALLATION 8 6 INITIAL START UP 10 7 OPERATION 11 8 CLEANING MAINTENANCE PROCEDURES 12 9 TROUBLESHOOTING 13 10 PARTS LISTS 14 11 WIRING DIAGRAMS 15 ...

Страница 4: ...EL AND OR DAMAGE TO EQUIPMENT UNIT MUST BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE CODES NOTICE The data plate is on top of the control box The griddle voltage wattage serial number wire size and clearance specifications are on the data plate This information should be carefully read and understood before proceeding with the installation NOTICE The installation of any components such as a vent...

Страница 5: ...e on this or any other LANG appliance must be performed by qualified personnel only Consult your authorized service station directory or call the factory at 314 678 6315 or www langworld com For the service station nearest you WARNING BOTH HIGH AND LOW VOLTAGES ARE PRESENT INSIDE THIS APPLIANCE WHEN THE UNIT IS PLUGGED WIRED INTO A LIVE RECEPTACLE BEFORE REPLACING ANY PARTS DISCONNECT THE UNIT FRO...

Страница 6: ...stainless steel The griddle surface is constructed of 1 thick highly polished steel to reduce hot and cold spots recovery problems and ensured even heat through out the griddle Control Box The Control box dimensions are 26 66cm Wide 4 10cm Deep and 7 1 8 18cm High The Sides Bottom and Rear walls are constructed of stainless steel Controls The 160 TT Griddle comes standard with three 550 thermostat...

Страница 7: ...mpletely assembled inside a wood frame covered by cardboard box and strapped to a skid Remove the cardboard cover cut the straps and remove the wood frame CAUTION THE GRIDDLE IS EXTREMELY HEAVY FOR SAFE HANDLING INSTALLER SHOULD OBTAIN HELP AS NEEDED OR EMPLOY APPROPRIATE MATERIALS HANDLING EQUIPMENT SUCH AS A FORKLIFT DOLLY OR PALLET JACK TO REMOVE THE UNIT FROM THE SKID AND MOVE IT TO THE PLACE ...

Страница 8: ...ling Griddle into Cabinet Turn the griddle over taking care not to kink the thermostat capillary tubes Set the griddle on the table that it is to be installed in leaving a hole big enough to slip the control panel through Insert the control panel through the hole and out the control opening of the cabinet The hole must be a minimum of 12 from the griddle and such that the control box can come out ...

Страница 9: ...Conn Three Phase Single Phase 208 Volt 240 Volt 480 Volt 208 V 240 V L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 18 0 50 0 50 0 50 0 43 3 43 3 43 3 21 7 21 7 21 7 80 5 75 0 Phasing Three Phase Single Phase INSTALLATION CONT D ...

Страница 10: ...h the griddle plate Rinse with a damp sponge and dry with a clean rag To season the griddle set the thermostat dial to 300 Allow unit to cycle once Apply a thin coat of high grade non salted vegetable oil to the griddle surface Rub the oil into the griddle surface with the flat side of a spatula or a towel Re coat any dry spots that appear then wait two minutes and wipe off any excess oil Repeat t...

Страница 11: ...ng should be done on outside one foot of the griddle The thermostats are provided with indicator lights that will go off when the griddle section reaches the set temperature Turn the thermostat dials to the desired cooking temperature and allow the indicator to cycle on and off a minimum of three times before beginning to cook If the product is loaded directly over the griddle thermostat the eleme...

Страница 12: ...the regular attention that it deserves the same as any other highly perfected machinery to insure best results and continued high operating efficiency CALIBRATION Calibration Check Place thermometer or thermocouple in the center of griddle Set thermostat to 350 F Allow the griddle to Preheat for at least half an hour Note cycle on temperatures and cycle off temperatures for 3 cycles Red indicator ...

Страница 13: ...ed service station directory or call the factory at 314 678 6315 or www langworld com For the service station nearest you WARNING BOTH HIGH AND LOW VOLTAGES ARE PRESENT INSIDE THIS APPLIANCE WHEN THE UNIT IS PLUGGED WIRED INTO A LIVE RECEPTACLE BEFORE REPLACING ANY PARTS DISCONNECT THE UNIT FROM THE ELECTRIC POWER SUPPLY If an item on the list is followed by an asterisk the work should be done by ...

Страница 14: ...ment 208 240Volt O S 4500 Watts 5991 Watts 2 160TT 208V12 2N 11030 29 GRIDLE ELEMENT 208V 240VOLT 4500 WATTS 5991 WATTS 3 160TT 208V18 240V18 2N 11030 30 Griddle Element Perimeter 208 Volt I S 1297 Watts 2 160TT 208V12 2N 11030 30 Griddle Element Perimeter 208 Volt I S 1297 Watts 3 160TT 208V18 2T 30402 07 Thermostat 550 F 48 Capillary Tube 2 160TT 208V12 2T 30402 07 Thermostat 550 F 48 Capillary ...

Страница 15: ...15 WIRING DIAGRAM 208 VOLT ...

Страница 16: ...17 WIRING DIAGRAM 240 480 VOLT ...

Отзывы: