manualshive.com logo in svg
background image

Star Manufacturing International 

10 Sunnen Drive   

St. Louis, MO.63143-3800 

Part Number: 2M-W478 

Ph: 314-781-2777 Fax: 314-781-2714 

Rev. B 

WWW.STAR-MFG.COM

  

 

June 19, 2007

 

 

 
Installation,  
Operation, Maintenance  
and Service Instructions 

Fryer 

Model: 130F 

Содержание 130f

Страница 1: ...International 10 Sunnen Drive St Louis MO 63143 3800 Part Number 2M W478 Ph 314 781 2777 Fax 314 781 2714 Rev B WWW STAR MFG COM June 19 2007 Installation Operation Maintenance and Service Instruction...

Страница 2: ...NIT MUST BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE CODES The data plate is located behind access door over tank drain The fryer voltage wattage serial number wire size and clearance specification...

Страница 3: ...authorized service agent directory or call the factory at 1 800 807 9054 or visit our website WWW STAR MFG COM for the service agent nearest you WARNING BOTH HIGH AND LOW VOLTAGES ARE PRESENT INSIDE T...

Страница 4: ...dels The interior dimensions are 36 91 5cm High 38 96 5cm Deep 15 38cm wide The Sides Bottom and Rear wall are constructed stainless steel Controls Easy to use manual control knobs Indicator lights fo...

Страница 5: ...of the fryer so that power may be brought in from below the unit Connect power cord to 3 Pole terminal block refer to wiring diagram Plug the hole on the rear panel when using bottom power entry Chec...

Страница 6: ...be activated by lifting the handle at either side of the fryer A drain valve is provided at the left front of the fryer Always turn the fryer power off before lifting the elements of draining the oil...

Страница 7: ...N position 208 240 VAC to POWER pilot lamp 208 240 VAC to Thermostat through Over Temperature thermostat Thermostat Set 208 240 VAC to HEAT pilot lamp 208 240 VAC to Contactors Contactors Energize 208...

Страница 8: ...ght sides of the fryer lower front In the event the fryer is built into a location all maintenance may be done from the front by removing the oil pot to gain access to the contactors To remove the pot...

Страница 9: ...tat Confirm that thermostat has 208 240 VAC to it Check that thermostat is operating properly Defective Contactor Confirm that contactor has 208 240 VAC to it Check contactor for normal operation 554...

Страница 10: ...WIRE DIAGRAMS 208 240 VOLT...

Страница 11: ...WIRE DIAGRAMS 480...

Страница 12: ...C28 Counter Model Fryer SK2294 Rev B 7 15 14 Marine Application 26 27 28 30 32 33 52 1 2 18 17 19 20 21 22 23 24 27 28 39 38 37 35 32 33 34 29 30 36 33 32 31 45 44 40 41 35 42 43 46 48 47 53 25 26 51...

Страница 13: ...TC 3POLE 40A208 240VAC ALL MODELS 12 O9 C28 111 2 1 CONTACTOR MOUNT SPOTWELD ALL MODELS 13 2E 30500 09 1 TRM BLOCK 3 POLE SMALL 95 ALL MODELS 14 2E 30500 01 AR TRM STRP 2 POLE 30A 300V ALL MODELS 15 Y...

Страница 14: ...EMENT BRACKET SUPPORT ALL MODELS 45 2C 20111 09 AR SCRW HXHD CAP 10 32X1 2 ALL MODELS 46 2N 11110 39 3 ELMNT FRYER 480V 4KW C28 130F 480V AND 480VM 2N 11110 43 ELMNT FRYER 208V 4KW C28 130F 208V AND 2...

Страница 15: ...age Coil OB 30700 05 208 240 Volts 554 Transformer Resistance Part Primary Resistance Secondary Resistance 2E 31400 04 480 Volts 66 240 Volts 16 Fryer Line Amperage and Wattage All Series 28 Electric...

Страница 16: ...STAR MANUFACTURING 10 Sunnen Drive St Louis MO 63143 U S A 800 807 9054 314 781 2777 Parts Service 800 807 9054 www star mfg com...