background image

5

SPECIFICATIONS

EQUIPMENT SPECIFICATIONS

Current Model

Volts AC

Hz.

PH

Kw 

Tot.

Amp 

1ph.

Sply 

Wire 

1ph

Amp 3 Ph

Sply 

Wire 

3ph

Kw 

Tot.

Amp 

1ph.

Sply 

Wire 

1ph

Amp 3 Ph

Sply 

Wire 

3ph

L1

L2

L3

L1

L2

L3

124T

208/240V

60

1/3

12

58

4

50

29

29

6

124T-220V

220V

50/60

1/3

10

45.5

6

39.4

22.7

22.7

8

124T-220VCW

220V

50/60

1/3

10

45.5

6

39.4

22.7

22.7

8

124T-380V

380V

60

3

12

27.3

15.7

15.7

10

124T-480V

480V

60

3

12

22

13

13

12

124T-480VSJ

480V

60

3

12

22

13

13

12

124T-BK

208/240V

60

1/3

12

58

4

50

29

29

6

124TC

208/240V

60

1/3

12

58

4

50

29

29

6

124TC-TE

208/240V

60

1/3

12

58

4

50

29

29

6

124THE

208/240V

60

1/3

12

58

4

50

29

29

6

124THE2L

208/240V

60

1/3

12

58

4

50

29

29

6

124T-PE

208/240V

60

1/3

12

58

4

50

29

29

6

124T-PE-480V

480V

60

3

12

22

13

13

12

124TSS

208/240V

60

1/3

12

58

4

50

29

29

6

124TSS-480V

480V

60

3

12

22

13

13

12

136T

208/240V

60

1/3

18

87

2

50

50

50

6

136T-480V

480V

60

3

18

22

22

22

12

136TC-TE

208/240

60

1/3

18

87

2

50

50

50

6

136TC-TE-380

380V

50

3

18

27

27

27

10

136TNTS

208/240V

60

1/3

18

87

2

50

50

50

6

148T

208/240V

60

1/3

24

116

1

75

75

50

3

148T-480V

480V

60

3

24

33

33

22

8

148TC

208/240V

60

1/3

24

116

1

75

75

50

3

148TC-TE

208/240V

60

1/3

24

116

1

75

75

50

3

148TC-TE-380

380V

50

3

24

41

41

27

6

148T-SJ

208/240V

60

1/3

24

116

1

75

75

50

3

148TSS

208/240V

60

1/3

24

116

1

75

75

50

3

148TSS-480V

480V

60

3

24

33

33

22

8

160T

208/240V

60

1/3

12

58

2

50

29

29

6

18

87

2

50

50

50

6

160T-480V

480V

60

3

12

22

13

13

12

18

22

22

22

12

160T-480VCP

480V

60

3

12

22

13

13

12

18

22

22

22

12

160TC-TE

208/240V

60

1/3

12

58

4

50

29

29

6

18

87

2

50

50

50

6

160TSS

208/240V

60

1/3

12

58

2

50

29

29

6

18

87

6

50

50

50

6

160TSS-480V

480V

60

3

12

22

13

13

12

22

22

22

12

172T

208/240V

60

1/3

18

87

2

50

50

50

6

18

87

2

50

50

50

6

172T-480V

480V

60

3

18

22

22

22

12

18

22

22

22

12

172T-480VSJ

480V

60

3

18

22

22

22

12

18

22

22

22

12

172TC

208/240V

60

1/3

18

87

2

50

50

50

6

18

87

2

50

50

50

6

172TC-TE

208/240V

60

1/3

18

87

2

50

50

50

6

18

87

2

50

50

50

6

172T-PE

208/240V

60

1/3

18

87

2

50

50

50

6

18

87

2

50

50

50

6

172T-PE-480V

480V

60

3

18

22

22

22

12

18

22

22

22

12

172T-SJ

208/240V

60

1/3

18

87

2

50

50

50

6

18

87

2

50

50

50

6

172TSS

208/240V

60

1/3

18

87

2

50

50

50

6

18

87

2

50

50

50

6

172TSS-480V

480V

60

3

18

22

22

22

12

18

22

22

22

12

Содержание 124T

Страница 1: ...ERMOSTATIC ELECTRIC GRIDDLE Commercial Marine 124T 124TC 124THE 124TSS 136T 136TC 136TNTS 148T 148TC 148TSS 160T 160TC 160TSS 172T 172TC 172TSS Installation and Operation Instructions 2M W352 Rev F 10...

Страница 2: ...SERVICE PERSONNEL ONLY NOTICE Using any part other than genuine Star factory supplied parts relieves the manufacturer of all liability Star reserves the right to change speci cations and product desig...

Страница 3: ...e 13 Troubleshooting Symptoms Possible Causes 14 Possible Causes Test 14 Wiring Diagram 208 240VAC 16 480VAC 17 Exploded View Parts List 18 23 PROBLEMS QUESTIONS or CONCERNS Before you proceed consult...

Страница 4: ...ATIONS Current Model Volts AC Hz PH Kw TOT Amp 1PH Supply Wire 1 PH Amp 3 Ph Kw TOT Amp 1PH Supply Wire 1 PH Amp 3 Ph Supply Wire 3 PH L1 L2 L3 L1 L2 L3 124T 380VM 380V 50 60 3 12 27 3 15 7 15 7 10 12...

Страница 5: ...8T 208 240V 60 1 3 24 116 1 75 75 50 3 148T 480V 480V 60 3 24 33 33 22 8 148TC 208 240V 60 1 3 24 116 1 75 75 50 3 148TC TE 208 240V 60 1 3 24 116 1 75 75 50 3 148TC TE 380 380V 50 3 24 41 41 27 6 148...

Страница 6: ...ch twelve inch section of the griddle is controlled by an area sensitive RTD probe which can sense and react to a temperature change of 4 F Each twelve inch section has a set of 6 K W elements for hig...

Страница 7: ...un crating move the oven as near to its intended location as practical The crating will help protect the unit from the physical damage normally associated with moving it through hallways and doorways...

Страница 8: ...NEL AND OR DAMAGE TO EQUIPMENT UNIT MUST BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE CODES NOTICE The data plate is located behind access panel between controls and grease drawer The grill voltage...

Страница 9: ...ddles Use a supply wire suitable for at least 90 C 194 F This griddle is shipped from the factory set up for a three phase service On 208V 220V 240V the wiring can be changed in the supply terminal ju...

Страница 10: ...e as the cooking surface passes the 300 F 148 C point Do not be alarmed as the smoke is caused by oils associated with the manufacturing process and will stop when the griddle reaches 350 F 176 C Seas...

Страница 11: ...side front or back of the temperature sensor the thermostat will react to the temperature change much slower During slow periods with minimal loads do not load directly over the thermostat sensors as...

Страница 12: ...burned on grease and food the griddle should be thoroughly scoured and re seasoned Use pumice or griddle stone while the griddle is warm Do not use steel wool because of the danger of steel slivers g...

Страница 13: ...y be used to wipe surface clean followed by wiping with clean wet cloth 3 Follow daily cleaning steps for Non Chrome Surfaces CAUTION ON CROME SURFACES 1 Never use pumice griddle stones or abrasives o...

Страница 14: ...APPLIANCE WHEN THE UNIT IS PLUGGED WIRED INTO A LIVE RECEPTACLE BEFORE REPLACING ANY PARTS DISCONNECT THE UNIT FROM THE ELECTRIC POWER SUPPLY If an item on the list is followed by an asterisk the work...

Страница 15: ...ING continued USE OF ANY REPLACEMENT PARTS OTHER THAN THOSE SUPPLIED BY LANG OR THEIR AUTHORIZED DISTRIBUTORS CAN CAUSE BODILY INJURY TO THE OPERATOR AND DAMAGE TO THE EQUIPMENT AND WILL VOID ALL WARR...

Страница 16: ...ICAL WIRING FOR EACH SECTION ON UNITS THAT HAVE A TYPICAL 208 220 V 240V INSTALL REMOVE JUMPER JUMPER ELEMENT HOOKUP ITEM 4 ITEM 4 AMPS 1 L1 L2 L2 L3 L1 L3 TOTAL L1 L2 L3 PHASE L1 L2 L3 L1 L2 208 6 0...

Страница 17: ...1 USE LG36 CONN 2 USE LG36 1 GRIDDLE ELEMENTS 2 GRIDDLE PILOT LAMP 3 GRIDDLE THERMOSTAT 4 TERMINAL BLOCK 3 2 32 8 7 NUMBER 6 5 13 3 29 2 30 1 4 3 11 3 27 2 28 1 2 1 9 3 25 2 26 1 MODELS 48OV 3PH Elec...

Страница 18: ...18 SK2397 Rev 8 15 08 1 2 3 4 5 6 7 8 9 14 10 17 15 16 18 19 20 21 10 24 23 25 26 27 10 10 10 29 32 30 22 22 12 13 10 31 10 11 28 Model Electric Thermostatic Griddle...

Страница 19: ...C T 124T 124T 220V 124THE2L 2T 30402 09 2 STAT ADJ 550 72 C T 124T 220VCW 124T 480V 124T PE 124T PE 480V 124TC TE 124TSS 124TSS 480V 2T 30401 30 1 STAT FXD 550 DEG OPEN 124THE2L 23 2C 20101 77 4 SCRW...

Страница 20: ...1 GROUNDING LUG LABEL ALL 13 2C 20202 06 1 WSHR LOCK 10 INT STAR ALL 14 2E 30500 07 1 TRM BLOCK 3PLELRGE 125AMP ALL 15 2C 20103 01 4 SCRW SM PLT 10X7 8 PHIL ALL 16 2E 30500 22 1 TRMINL STRP 8POLE 50A2...

Страница 21: ...8T 440VM 148T 480V M 148TC TE 380 148TSS 480V 15 2C 20103 01 4 SCRW SM PLT 10X7 8 PHIL 148T 148T M 148TC 148TH 208 240V 148T SJ 148TC TE 148TSS 148THS 208 240V 16 2E 30500 22 1 TRMINL STRP 8POLE 50A25...

Страница 22: ...30500 22 2 TRMINL STRP 8POLE 50A250V 160T 17 K9 XL 507 2 REAR COVER 160T 18 2C 20104 04 6 SCRW PHD ST 8 32X 5 PLTD PHILP 160T 19 2P 70803 02 2 PLG BTN PLTD MTL 1 2 160T 208 240V 2P 70803 02 8 PLG BTN...

Страница 23: ...R 172T 172T M 14 2E 30500 07 2 TRM BLOCK 3PLELRGE 125AMP 172T 172T 440VM 172T 480V 172T 480VSJ 172T PE 480V 172TSS 480V 15 2C 20103 01 12 SCRW SM PLT 10X7 8 PHIL 172T 16 2E 30500 22 2 TRMINL STRP 8POL...

Отзывы: