10Base-T/100Base-TX/E1 converter
Operating Manual
_______________________________________________________________________________
IOA78-1C 33 January 2005
6.3. Environmental requirements
6.3.1. Operation
The converter may operate indoors, in unevenly heated rooms, in the following ambient
conditions:
Environmental parameter
Acceptable value
Ambient temperature
+5
÷
+40
O
C
Air relative humidity
≤
80% at a temperature of +20
O
C
6.3.2. Transport
The devices in factory packaging should be transported in the following conditions:
Environmental parameter
Acceptable value
Ambient temperature
-25
÷
+40
O
C
Temperature variation rate
≤
10
O
C/h
Maximum air humidity
95%
Atmospheric pressure
700
÷
1060 hPa
Multiple strokes
5
÷
15 g in 10 ms
6.3.3. Storage
Converters should be stored indoors, in the following ambient conditions:
Environmental parameter
Acceptable value
Ambient temperature
-25
÷
+55
O
C
Humidity
5% to 90% over +40
O
C
Vibrations
frequency: 10 Hz to 55 Hz, amplitude: 0.15 mm
duration: 10 cycles in three planes
Level of pollution
typical home or office environment
6.4. Electromagnetic compatibility
Converters conform to requirements for A class devices regarding radio/electrical interference
as set out in the PN-EN 55022 standard,
provided that they have been installed in accordance with
this manual.
Warning:
This is a Class A device. In a domestic environment this product may cause radio and electrical interference
in which case the user may be required to take adequate measures.
6.5. Power Supply
Parameter
Value
Rated supply voltage
4,5
÷
5,5 V; 0 Hz
Maximum rated power input
800 mA
Type of connection
double clamped (screwed) joint