Installation and placement of toilet

L&T

®

 Duomatic can be installed in an existing or new building. On the toilet cardboard package you will find a tem-

plate you can use to outline the required apertures for the walls and floors of the building. The toilet can be installed 
directly on bearing soil ground, but we do recommend installation on top of lightweight blocks in order to facilitate 
servicing and ascertain sufficient ventilation.
It is important to make sure that the toilet is installed on an even ground. We recommend installation on non-freezing 
gravel bedding.

1.

  Cut out the templates on the L&T

®

 Duomatic box and use them to outline placement of the apertures on the floor

 

and wall. Use a jigsaw to cut along the lines.

2.

  Detach the rear cover of the toilet. Take out the inside container and the lid to facilitate installation.

3.

  Install the toilet chassis. We recommend that you place 50 mm light-weight gravel blocks under the toilet to 

 

secure ventilation.

4.

  Fix the toilet chassis to the toilet building using the 25 mm screws included in the package.

5.

  Make sure that the evaporation plate is tightly fixed and that the insect net at the ventilation opening fits tightly.

6.

  Put the composting containers in place and check that the screen plates are placed correctly (on top of net, 

 

below fabric). Add a layer of some 5 cm of L&T Bio-Life

®

 drying agent at the bottom of the containers.

7.

  Fix the rear cover.

8.

  Fasten the overflow/seepage hose and connect it to the seepage canister. The seepage canister should be dug

 

into the ground. PLEASE NOTE! Seepage must not be drained directly into the ground!

9.

  Install the 110 mm sewer/ventilation pipe (not included in the package, available at hardware stores). 

 

The pipe end must be placed at least 70 cm above the ridge of the building.

10.

  Put the front cover and the thermal seat in place.

11.

  The product is ready for use. Always close the thermal seat cover after use to make sure not to disturb the 

 

efficient ventilation of the toilet, and to ascertain proper operation.

UK

1

8

4

9

7

10

2

3

Содержание Duomatic

Страница 1: ...1 L T Duomatic kompostik ym l L T Duomatic komposterande toa L T Duomatic composting toilet L T w w w l a s s i l a t i k a n o j a c o m...

Страница 2: ...aineella joista parhaiten t h n tarkoitukseen sopii turpeesta ja kutterilastusta valmistettu L T Bio Life K ym l n l mp istuimen kansi on syyt pit suljettuna aina k ytt kertojen v lill ettei tehokas i...

Страница 3: ...ostik ym l n osakuva 1 Runko 2 Irrotettava takakansi 3 Sis astia 4 Suodatinkangas ja verkko 5 Irrotettava yl kansi 6 L mp istuin 7 Haihdutuslevy 8 Ylivuotoletku 9 Suotonestekanisteri 10 Ilmastointiput...

Страница 4: ...isteriin joka tulee kaivaa maahan HUOM Suotonestett ei saa johtaa suoraan maaper n 9 Asenna 110 mm viem ri ilmastointiputki paikoilleen ei sis lly pakkaukseen saatavilla rautakaupoista Putken p tulee...

Страница 5: ...junta aineita Jos kompostik ym l ss kompostoidaan my s keitti n bioj tteit on syyt muistaa peitell bioj tteet huolellisesti kuivikeaineella L T Bio Life aina bioj tteiden lis misen j lkeen Haju L mp k...

Страница 6: ...ing rinner den s k filtrerv tskan direkt i kanistern Vi rekommenderar att du efter varje anv ndning t cker avfallet l tt med kompoststr L T Bio Life som r tillverkat av torv och kuttersp n r mycket l...

Страница 7: ...rtiell illustration 1 Stomme 2 Avtagbart bakre lock 3 Innanbeh llare 4 Filtertyg och n t 5 Avtagbart vre lock 6 V rmesits 7 Avdunstningsplatta 8 versv mningsslang 9 Kanister f r filtrerv tska 10 Hatt...

Страница 8: ...nder toan f r att s kers t lla ordentlig ventilation 4 F st toans stomme vid byggnadens v gg med medf ljande 25 mm skruvar 5 Kolla att avdunstningsplattan sitter stadigt d r den ska och att ventilatio...

Страница 9: ...o avfall fr n k ket i komposttoan ska man komma ih g att noggrant t cka bioavfallet med kompoststr L T Bio Life varje g ng man l gger i bioavfall Lukt V rmesitsens lock ska alltid st ngas efter anv nd...

Страница 10: ...aste with a thin layer of drying agent after each toilet visit L T Bio Life made of peat and cutter shaving is your best choice In order not to disturb the efficient ventilation system the thermal toi...

Страница 11: ...2 Detachable rear cover 3 Inside container 4 Filter fabric and screen 5 Detachable upper lid 6 Thermal seat 7 Evaporation plate 8 Overflow hose 9 Seepage canister 10 Ventilation pipe cap 11 Ventilatio...

Страница 12: ...avel blocks under the toilet to secure ventilation 4 Fix the toilet chassis to the toilet building using the 25 mm screws included in the package 5 Make sure that the evaporation plate is tightly fixe...

Страница 13: ...ver the biowaste carefully with drying agent L T Bio Life after each portion of biowaste added Odour Always close the thermal seat cover after use in order to make sure not to disturb the efficient ve...

Страница 14: ...14 RUS L T L T L T L T 80 70 4 L T L T L T L T L T L T 70 4 1 5 V353100 2 80 30 420 875 780 100...

Страница 15: ...15 RUS L T 1 2 3 4 5 6 7 8 9 10 11 12 13 L T...

Страница 16: ...16 RUS L T 1 L T 2 3 4 25 5 6 5 L T 7 8 9 110 70 10 11 1 8 4 9 7 10 2 3...

Страница 17: ...17 RUS 1 2 3 4 5 6 70 L T L T 358 10 636 2790 3 4 6...

Страница 18: ...18...

Страница 19: ...19...

Страница 20: ...Products Sentnerikuja 1 00440 Helsinki FINLAND Phone 358 0 10 636 2790 Fax 358 0 10 636 2700 Pakannut ja tarkistanut pvm Packat och kontrollerat av datum Packaged and inspected Date 0109 PM Painettu...

Отзывы: