![Landoll LT10A Series Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/landoll/lt10a-series/lt10a-series_operators-manual_3607878025.webp)
5-1
Chapter 5
Troubleshooting Guide
Troubleshooting should be performed by a trained and
competent technician. Landoll Corporation is not
responsible for equipment that is improperly maintained.
Contact an authorized Landoll dealer or the Landoll
Service department for service questions.
Electrical
Most electrical system problems show up as a burned out
light or fuse, or inoperative electrical component. Wiring,
grounds or components may be at fault. Locate the
symptom in this section that best identifies your electrical
problem. Check out each possible problem under that
symptom. If the problem cannot be located, see an
automotive electrical specialist. For maintenance
procedures, see
“Electrical System” on page 4-5.
PROBLEM
PROBABLE CAUSE
SOLUTION
NO LIGHTS
Fuse blown
Replace fuse
Loose Connection at plug-in
Tighten connection
Broken or corroded wires
Replace wire
Ground wire loose
Clean and tighten ground
LIGHTS FLICKERING
Wires shorted or loose
Locate, insulate, replace, or tighten
LIGHTS DIM
Voltage difference between trailer and
tractor
Tractor supply wire or circuit components
too low capacity
Enlarge wire or component, match bulbs
with tractor voltage
LIGHTS BRIGHT AND BURN OUT
Voltage difference between trailer and
tractor
Tractor supply wire or circuit components
too low capacity
Enlarge wire or component, match bulbs
with tractor voltage
Ground wire disconnected
Self-explanatory
FUSE BLOW-OUT OR CIRCUIT
BREAKER TRIPPING
Vibration
Locate source of vibration and repair
Short circuit
Replace fuse and try all accessories
If fuse blows right away, locate short and
repair
LAMP BULB BURN OUT
Vibration
Locate source of vibration and repair
Short circuit
Replace fuse and try all accessories
If fuse blows right away, locate short and
repair
Loose connection
Check lamp sockets and ground
connections
Intermittent short
Locate short and repair
Improper voltage
Check voltage regulator output
Содержание LT10A Series
Страница 2: ......
Страница 16: ...3 6 F 876 1217 Edition OPERATING INSTRUCTIONS Table provided for general use NOTES...
Страница 24: ...4 8 F 876 1217 Edition MAINTENANCE AND LUBRICATION Page Intentionally Blank...
Страница 34: ...5 10 F 876 1217 Edition TROUBLESHOOTING GUIDE Table provided for general use NOTES...
Страница 35: ......