4-44
F-1058-0820
OPERATION AND MAINTENANCE
Password
The password function allows you to protect the total acre
count, pulses per 400 feet, and width settings with a
password. This stops anyone from accidentally changing
those settings. When the acre counter is shipped, the
password is disabled. You can modify the pulses per 400
feet and implement width at any time.
Press the
FUNC
button until the “
P-WORD
” LED is lit.
The digits will display the word “
Ent
” or “
dIS
”.
1.
If the display shows “
dIS
”
The password is disabled. The total acre count,
pulses/400 ft, width, and password settings can be
adjusted using the
UP
and
DOWN
buttons. The
password can also be changed using the
UP
and
DOWN
buttons.
Figure 4-50: Password Disabled
2.
If the display shows “
Ent
”
a.
You must enter your password using the
UP
and
DOWN
buttons. When your password is
displayed, press the
FUNC
button to test the
password. If the password is correct, you will be
able to change the acre counter settings. The
password will be viewable until the acre counter
powers down. When the acre counter is powered
up again, you will have to re-enter the password
to change settings.
Figure 4-51: Enter Password
b.
If the password is not correct, you will not be able
to change the acre counter settings. When the
“
P-WORD
” function is selected again, “
Ent
” will
appear in the display.
dIS
Acre Counter
*
FIELD
TOTAL PULSES WIDTH P-WORD BATT
ACRES
Ent
Acre Counter
*
FIELD
TOTAL PULSES WIDTH P-WORD BATT
ACRES