![Landis+Gyr ZFQ202 Скачать руководство пользователя страница 78](http://html1.mh-extra.com/html/landis-gyr/zfq202/zfq202_user-manual_673734078.webp)
Gyr
H 71 0200 0215 f en - ZMQ202 / ZFQ202 - User Manual
78/88
Maintenance
Operating display
1.
All segments of the
display are
illuminated
Display check
2.
R
Enter service menu
Set mode
3.
Enter set mode
Identification
number
4.
Select required
setting
Date, old value
5.
R
Select digit to be
changed
Digit flashes
6.
Change digit value
Digit flashes
7.
R
Select digit to be
changed
Next digit flashes
8.
Repeat steps 5 - 7 for all digits to be changed
Al digits flash
simultaneously
9.
R
Confirm new
setting
Date, new value
10.
Repeat steps 3 - 8 for all settings to be changed
11.
Advance display until
End
12.
Back to service
menu
End of set mode
7.3 Change
Battery
7.3.1
When to Change Battery
If the meter is provided with a battery, this must be changed if one of the
following events occurs:
•
The
symbol appears in the liquid crystal display.
•
During the normal calibration cycle of the meter.
•
The battery charge indicates less than 4.8 V (can be read under code
C.6.1 in service list).
Note
Indication of symbol “BAT LOW”
Only meters with the parameter set to allow the battery symbol
will display it at a low battery condition.
The meter functions perfectly well without a battery.
Содержание ZFQ202
Страница 4: ...Landis Gyr H 71 0200 0215 f en ZMQ202 ZFQ202 User Manual 4 88 ...
Страница 28: ...Landis Gyr H 71 0200 0215 f en ZMQ202 ZFQ202 User Manual 28 88 Description of Unit ...
Страница 54: ...Landis Gyr H 71 0200 0215 f en ZMQ202 ZFQ202 User Manual 54 88 Installation De installation ...
Страница 66: ...Landis Gyr H 71 0200 0215 f en ZMQ202 ZFQ202 User Manual 66 88 Operation ...
Страница 74: ...Landis Gyr H 71 0200 0215 f en ZMQ202 ZFQ202 User Manual 74 88 Service ...
Страница 84: ...Landis Gyr H 71 0200 0215 f en ZMQ202 ZFQ202 User Manual 84 88 Maintenance ...
Страница 86: ...Landis Gyr H 71 0200 0215 f en ZMQ202 ZFQ202 User Manual 86 88 Disposal ...